3
Operation
3.1
Ensuring Power Supply
The PCAN-Router Pro FD must be supplied with a nominal 12 V DC
voltage (8 to 32 V possible) via the power connector.
Note:
If you install a backup battery (see section 4.4) and it is
charged, the device can also be operated without a power
supply (e.g. in the event of a power failure).
3.2
Starting the PCAN-Router Pro FD
The PCAN-Router Pro FD is automatically switched on when the
supply voltage is applied (power LED lights up). By default, six
transceiver modules with wake-up function are installed.
If other transceiver modules without wake-up function are installed
on request, an external wake-up signal via pin 1 of the power
connector from 3 to 32 Volt is required (see section 4.1 on page 16).