PCAN-Router Pro FD – User Manual
18
If the PCAN-Router Pro FD is restarted, it automatically detects the
type of the installed CAN transceiver module and sets the
transmission standard (see table above) for the CAN channel
accordingly.
Note:
If one or more transceiver modules without wake-up
function are installed, an external wake-up signal via pin 1 of
the power connector is required. Only then the device or the
respective transceiver will be powered on.
4.2
Setting the Termination for a CAN Bus
Depending on the CAN transceiver modules used, you can use the
switch blocks
on the front panel to set a CAN bus termination for
CAN 1 to CAN 6 (
C1
to
C6
). On delivery, the switch blocks are set to
off
.
Tip:
We recommend adding termination at the CAN cabling, for
example with termination adapters (e.g. PCAN-Term). Thus,
CAN nodes can be flexibly connected to the bus.
Figure 9: Positions of the switch blocks for CAN termination on the front board