![Peak IPEH-002220 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/peak/ipeh-002220/ipeh-002220_user-manual_1517070040.webp)
PCAN-Router Pro FD – User Manual
40
Value Range
Description
1 to 4000000000
Tracing is stopped after this duration.
!1 to !4000000000 By adding
!
the device is shut down after the specified duration.
7.2.10
Beep Patterns
With these settings beep patterns for the events trace start, stop,
and error are specified. The general structure of a beep pattern
configuration is as follows:
KEYWORD=Repetition Tick-Duration Pattern
Parameter
Description
Repetition
A number from 1 to 4000000000 indicates how often the pattern
is repeated. If 0 is indicated, the pattern is repeated endlessly.
Tick-Duration
This value defines the duration of a single tick in milliseconds
with a maximum of 4000000000.
Pattern
A beep pattern is built with up to 64 x or _ characters.
x = The beeper is on for the duration of one tick.
_ = The beeper is off for the duration of one tick.
Important note:
A pattern should end with _ since the last value
is kept. If the pattern ends with x, the device would not stop
beeping until the next pattern starts. With the configuration
KEYWORD=1 50 _
the device can be muted for the event.
TRC_START_BEEP
defines a beep pattern for the event trace start.
TRC_START_BEEP=1 50 xx__xx______xxxx_
TRC_STOP_BEEP
defines a beep pattern for the event trace stop.
TRC_STOP_BEEP=1 50 xx__xx______xxxx_