![Paul CLIMOS F 200 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/paul/climos-f-200/climos-f-200_original-operating-instructions_4022625048.webp)
48
Maintenance and repair by qualified personnel
3.7
If regular maintenance work is not performed at the CLIMOS, this impairs the functioning
of the comfort ventilation.
The maintenance and repair by qualified personnel should only be carried out by a maintenance service
on the basis of a maintenance contract. The maintenance and repair measures for the CLIMOS include
the inspection and cleaning of the fans and the heat exchanger. Cleaning of the heat exchanger is carried
out depending on the degree of soiling; the maintenance interval should not exceed two years.
The maintenance work performed must be documented in check list B!
Inspecting and cleaning the heat exchanger
3.7.1
In order to do so, proceed as follows:
1. Disconnect the CLIMOS from the power supply.
2. If applicable, pull the red design filter covers
A
out of the casing cover’s holder.
Fig 44: Pull out 2x design filter covers
A
3. Open the quarter turn locks
B
by turning the captive screw by 90°.
Fig 45: Casing cover with 4x quarter turn lock
B
B
A
Содержание CLIMOS F 200
Страница 1: ...Version 2 0_06 2016 EN...
Страница 57: ...57 Dimensional sketch 3 9 4 Fig 55 Dimension drawing HRU CLIMOS...
Страница 58: ...58 Circuit diagram CLIMOS Basic series 3 9 5 Fig 56 Terminal assignment CLIMOS Basic...
Страница 59: ...59 Circuit diagram CLIMOS Comfort series 3 9 6 Fig 57 Terminal assignment CLIMOS Comfort...
Страница 60: ...60 Terminal scheme master controller 3 9 7 Fig 58 Terminal assignment Master Controller...
Страница 65: ...65 Product fiche 4 5...