Verringerung / Erhöhung
Lüfterstufen 1 bis 7
Boost ventilation mode
Supply air and extract air mode
Extract air mode
Supply air mode
Filter change / reset filter run-
time
Avaiable control modules
2.2
The CLIMOS can be equipped with the following control modules:
•
Control unit LED control panel (w x h x d in mm: 80 x 80 x 12)
•
Control unit TFT touch panel (w x h x d in mm: 102 x 78 x 14)
•
External boost ventilation switch (any number, potential-free)
•
External sensors with sensor signal 0-10 V or 4-20 mA
These control modules are explained in more detail in the following sections.
LED control panel
2.2.1
The LED control panel has 7 symbolized short-stroke keys. By pressing a key or key combination, the
corresponding operations are performed. The active mode of operation is signaled by means green or red
LED. For the LED control panel in the design of the
PEHA
switch range, both on-wall and in-wall
installation is possible. In the case of surface mounting a
PEHA
surface box is required.
2.2.1.1 Operating functions LED control panel
Symbol
Designation
Explanation
Key
Supply air and extract
air mode
By pressing this key, the supply and extract air mode are
set.
Key
Extract air mode
By pressing this key, only the extract air mode is set. The
supply air mode is switched off.
If the ventilation device is operated with a
heat-producing appliance, this key must be
permanently deactivated! The simultaneous
operation of ventilation plant and heat-producing
appliance requires increased safety-related
requirements for negative pressure monitoring with a
switch-off function for the ventilation device.
Key
Supply air mode
By pressing this key, only the supply air mode is set. The
extract air mode is switched off.
Key
Decrease fan speed
By pressing this key, the fan speed is gradually decreased.
Key
Increase fan speed
By pressing this key, the fan speed is gradually increased.
Key
Boost ventilation mode
By pressing this key, the boost ventilation is activated for
15 minutes in the supply air and extract air mode at the fan
speed 7. After the expiration of the boost ventilation time,
the previously active operating mode is activated. By
Fig 3: Control and information fields of the LED control panel
Содержание CLIMOS F 200
Страница 1: ...Version 2 0_06 2016 EN...
Страница 57: ...57 Dimensional sketch 3 9 4 Fig 55 Dimension drawing HRU CLIMOS...
Страница 58: ...58 Circuit diagram CLIMOS Basic series 3 9 5 Fig 56 Terminal assignment CLIMOS Basic...
Страница 59: ...59 Circuit diagram CLIMOS Comfort series 3 9 6 Fig 57 Terminal assignment CLIMOS Comfort...
Страница 60: ...60 Terminal scheme master controller 3 9 7 Fig 58 Terminal assignment Master Controller...
Страница 65: ...65 Product fiche 4 5...