![background image](http://html1.mh-extra.com/html/patton-electronics/smartnode-series/smartnode-series_software-configuration-manual_4048643276.webp)
Using the AdventNet SNMP utilities
276
SmartWare Software Configuration Guide
25 • SNMP configuration
-
Message
that by default has the object identifier format (sequence of numeric or textual labels on the SNs
along a path from the root to the object) of the trap if any, or it is blank.
•
The details of the traps can be viewed by clicking the
Trap Details
button or right click the trap in the trap
table and select the option
View Trap Details
.
Figure 43
show the screen of such a trap details window.
Figure 43. AdventNet Trap Details window of TrapViewer
The various details available in the Trap Details window are listed in
table 12
:
Table 12. Details available in the Trap Details window
Trap Details
Description
TimeStamp
The TimeStamp is a 32-bit unsigned value indicating the number of hundredths-of-a-second
that have elapsed since the (re)start of the SNMP agent and the sending of the trap. This
field shows the value stored in the MIB-II sysUpTime variable converted into hours, minutes
and seconds.
Enterprise
This field shows the OID of the management enterprise that defines the trap message. The
value is represented as an OBJECT IDENTIFIER value and has a variable length.
Generic Type
The Generic type value is categorized and numbered 0 to 6. They are 0-coldStart, 1-warm-
Start, 2-linkDown, 3-linkUp, 4-authenticationFailure, 5-egpNeighborLoss. The trap type
value 6 is identified as enterprise-specific value. This field shows the value based on the
type of trap.
Specific Type
The specific trap type indicates the specific trap as defined in an enterprise-specific MIB. If
the Generic type value is 6 then, this field shows a value greater than 0. If the generic type
value is a value other than 6, then the field shows a value 0. This field can have values
from 0 to 2147483647.
Message
This is a text field. By default, this field will always contain the Varbinds in the Trap PDU.
This can be substituted with text.
Severity
This field shows the Severity or the intensity of the trap. They could be 0-All, 1-Critical, 2-
Major, 3-Minor, 4-warning, 5-Clear and 6-info.
Содержание SmartNode Series
Страница 250: ...RIP configuration task list 250 SmartWare Software Configuration Guide 23 RIP configuration rip enabled ...
Страница 635: ...635 Appendix A Terms and definitions Chapter contents Introduction 636 SmartWare architecture terms and definitions 636 ...
Страница 641: ...641 Appendix B Mode summary Chapter contents Introduction 642 ...
Страница 648: ...648 Appendix D Internetworking terms acronyms Chapter contents Abbreviations 649 ...
Страница 653: ...653 Appendix E Used IP ports available voice codecs Chapter contents Used IP ports 654 Available voice codecs 655 ...