Before using the serial interface the hardware port protocol has to be specified. There are two command
options available to select the suitable hardware port protocol:
•
v35
for V.35 protocol to be used
•
x21
for X.21 protocol to be used
Mode:
Administrator execution
Example:
Configuring the hardware port protocol
The following example enables X.21 as hardware port protocol for the serial interface on slot 0 and port 0.
Check that
Hardware Port
is set to
X.21
in the command output of
show port serial
.
node(cfg)#port serial 0 0
node(prt-ser)[0/0]#hardware-port x21
node(prt-ser)[0/0]#show port serial
Serial Interface Configuration
------------------------------
Port : serial 0 0 0
State : CLOSED
Hardware Port : X.21
Transmit Edge : normal
Port Type : DTE
CRC Type : CRC-16
Max Frame Length: 2048
Recv Threshold : 1
Encapsulation : framerelay
Configuring the active clock edge
Depending on the system configurations—i.e. when using long cables, with certain modem types or data
rates—synchronization problems may occur on the serial port. In these cases, it may be necessary to configure
the clock edge on which data is transmitted.
This procedure describes how to set the active clock edge of the serial interface
Mode:
Port serial
Step
Command
Purpose
1
node
(cfg)#port serial
slot port
Selects the serial interface on slot and port
2
node
(prt-ser)[
slot/port
]#hardware-port {v35 | x21}
Sets the hardware port protocol
3
node
(prt-ser)[
slot/port
]#show port serial
Displays the serial interface configuration
Step
Command
Purpose
1
node
(prt-ser)[
slot/port
]# transmit-data-
on-edge positive
Configures the serial interface to transmit on the
positive edge of the clock (normal, default).
2
node
(prt-ser)[
slot/port
]# transmit-data-
on-edge negative
Configures the serial interface to transmit on the
negative edge of the clock (inverted).
Содержание SmartNode Series
Страница 250: ...RIP configuration task list 250 SmartWare Software Configuration Guide 23 RIP configuration rip enabled ...
Страница 635: ...635 Appendix A Terms and definitions Chapter contents Introduction 636 SmartWare architecture terms and definitions 636 ...
Страница 641: ...641 Appendix B Mode summary Chapter contents Introduction 642 ...
Страница 648: ...648 Appendix D Internetworking terms acronyms Chapter contents Abbreviations 649 ...
Страница 653: ...653 Appendix E Used IP ports available voice codecs Chapter contents Used IP ports 654 Available voice codecs 655 ...