Displaying the alarms window
41
mDSL DACS Administrators’ Reference Guide
6 • Alarms
The mDSL Multiplexer has four methods to notify an alarm condition:
1.
Front panel LED—The front panel ALARM LED has three states that indicate the presence and severity
of an alarm. The states are:
-
Off—No alarm present
-
Solid—Minor alarm
-
Flashing—Major alarm.
Note
The POWER LED will flash if a power supply failure alarm is
present. If both power supplies are functioning normally, the LED
will be lit constantly. Otherwise, the LED will flash.
2.
Administration web page indication—The Alarms window of the administration page uses red highlight-
ing to indicate which items are in an alarm state (see figure 12).
Figure 12. Sample alarm indication
3.
SYSLOG/SNMP—For external notification, the DACS can be configured to send a SYSLOG message or
an SNMP TRAP to an external management host. To configure the alarm response for either SNMP Traps
or SYSLOG messages, click on the
Alarm Response
link (go to “Alarm Parameters” on page 44).
4.
Alarm Relay—Located on the rear of the chassis, the Alarm Relay is a 3-position terminal block. The
Alarm Relay may be configured to indicate when a major alarm, a minor alarm or both major and minor
alarms occur. It may also be disabled. The 3-position terminal block numbers its pins from 1 to 3 from left
to right. When no alarms are indicated, pins 1 and 2 are normally closed and pins 2 and 3 are normally
open. Upon the occurrence of an alarm—the type is configured as major, minor, or both—pins 1 and 2 are
open and pins 2 and 3 are closed.
Besides enabling a user to view current alarm status, you may manually generate an alarm as a test and clear the
alarm time and count variables. The Alarms main window also contains links to the following:
•
Modify Response—for configuring how the Alarm Response Outputs notify administrators of an alarm (see
“Alarm Parameters” on page 44)
•
Modify Alarms—Clicking on this link takes you to a window where you can configure the importance or
severity of each individual alarm. The severity of the alarm type may generate a minor, major, minor self-
Содержание 3095
Страница 20: ...About this guide mDSL DACS Administrators Reference Guide 18...
Страница 24: ...1 Introduction mDSL DACS Administrators Reference Guide 22 Saving HTTP HTML Object Changes...
Страница 29: ...27 Chapter 3 Import Export Chapter contents Introduction 28 Export Configuration 28 Import Configuration 30...
Страница 40: ...5 System History mDSL DACS Administrators Reference Guide 38 mDSL History table...
Страница 50: ...6 Alarms mDSL DACS Administrators Reference Guide 48 Modify Alarms Configuring alarm severity levels...
Страница 56: ...7 DS0 Mapping mDSL DACS Administrators Reference Guide 54 Displaying the DS0 Mapping window...
Страница 96: ...11 Filter IP mDSL DACS Administrators Reference Guide 94 Defining a filter...
Страница 97: ...95 Chapter 12 Frame Relay Chapter contents Introduction 96...
Страница 122: ...15 TCP mDSL DACS Administrators Reference Guide 120 TCP Details...
Страница 126: ...16 UDP mDSL DACS Administrators Reference Guide 124 Introduction...
Страница 132: ...17 RIP Version 2 mDSL DACS Administrators Reference Guide 130 RIP Version 2 Statistics...
Страница 138: ...18 SNMP mDSL DACS Administrators Reference Guide 136 Out...
Страница 150: ...19 System mDSL DACS Administrators Reference Guide 148 System Packet Holding Message Blocks...
Страница 180: ...21 T1 E1 Link mDSL DACS Administrators Reference Guide 178 Far End Line Statistics Totals...
Страница 185: ...183 Chapter 23 About Chapter contents Introduction 184 Patton Electronics Company contact information 184...
Страница 190: ...24 License mDSL DACS Administrators Reference Guide 188 End User License Agreement...
Страница 191: ...189 Appendix A Network Ports RJ 21X connector pin out Chapter contents Introduction 70...
Страница 194: ...A Network Ports RJ 21X connector pin out mDSL DACS Administrators Reference Guide 192 Introduction...
Страница 195: ...193 Appendix B WAN Network Module connector pin out Chapter contents Introduction 194...
Страница 199: ...Introduction 197 DSL DACS Administrators Reference Guide B WAN Network Module connector pin out...
Страница 200: ...B WAN Network Module connector pin out DSL DACS Administrators Reference Guide 198 Introduction...