System Status parameters
33
mDSL DACS Administrators’ Reference Guide
4 • System Status
•
rate15sec(15)—Refresh every 15 seconds
•
rate30sec(30)—Refresh every 30 seconds
•
rate1min(60)—Refresh every minute (60 seconds)
•
rate2min(120)—Refresh every 2 minutes (120 seconds)
•
rate3min(180)—Refresh every 3 minutes (180 seconds)
•
rate5min(300)—Refresh every 5 minutes (300 seconds)
Click
Submit Query
after selecting the desired refresh rate.
System Status parameters
The system status table displays the following parameters:
•
Alarm—If the Alarm is flashing red, there is an alarm condition in the box. For further information on the
alarm, review the alarms in the other tables on this web page or refer to Chapter 6, “Alarms” on page 39.
•
Box Temp.—Displays the internal temperature in degrees Centigrade.
•
Power Supply 1
•
Power Supply 2
•
Main Clock
•
Fallback Clock.
The Box Temp. reading is displayed in degrees Centigrade. The status of the remaining parameters is shown by
one of the following symbols:
•
Green square: No alarms are present and functioning properly.
•
Red flashing star: An alarm or alarms are present.
If there is a flashing red indicator, go to the appropriate chapter listed in Table 3.
Navigating the WAN Port Information parameters
The following WAN circuit categories are available:
•
Configure—Clicking one of these links displays a WAN Circuit Configuration Link window for configur-
ing a WAN port.
•
Circuit ID—This is the name given to the WAN circuit.
Table 3. System status/subsystem reference
System status
Subsystem
Alarm
Chapter 6, “Alarms” on page 39
Box Temp.
Chapter 6, “Alarms” on page 39
Power Supply S1
Power Supply S2
Chapter 6, “Alarms” on page 39
Main Clock
Fallback Clock
Chapter 6, “Alarms” on page 39 and Chapter
8, “System Clocking” on page 55
Содержание 3095
Страница 20: ...About this guide mDSL DACS Administrators Reference Guide 18...
Страница 24: ...1 Introduction mDSL DACS Administrators Reference Guide 22 Saving HTTP HTML Object Changes...
Страница 29: ...27 Chapter 3 Import Export Chapter contents Introduction 28 Export Configuration 28 Import Configuration 30...
Страница 40: ...5 System History mDSL DACS Administrators Reference Guide 38 mDSL History table...
Страница 50: ...6 Alarms mDSL DACS Administrators Reference Guide 48 Modify Alarms Configuring alarm severity levels...
Страница 56: ...7 DS0 Mapping mDSL DACS Administrators Reference Guide 54 Displaying the DS0 Mapping window...
Страница 96: ...11 Filter IP mDSL DACS Administrators Reference Guide 94 Defining a filter...
Страница 97: ...95 Chapter 12 Frame Relay Chapter contents Introduction 96...
Страница 122: ...15 TCP mDSL DACS Administrators Reference Guide 120 TCP Details...
Страница 126: ...16 UDP mDSL DACS Administrators Reference Guide 124 Introduction...
Страница 132: ...17 RIP Version 2 mDSL DACS Administrators Reference Guide 130 RIP Version 2 Statistics...
Страница 138: ...18 SNMP mDSL DACS Administrators Reference Guide 136 Out...
Страница 150: ...19 System mDSL DACS Administrators Reference Guide 148 System Packet Holding Message Blocks...
Страница 180: ...21 T1 E1 Link mDSL DACS Administrators Reference Guide 178 Far End Line Statistics Totals...
Страница 185: ...183 Chapter 23 About Chapter contents Introduction 184 Patton Electronics Company contact information 184...
Страница 190: ...24 License mDSL DACS Administrators Reference Guide 188 End User License Agreement...
Страница 191: ...189 Appendix A Network Ports RJ 21X connector pin out Chapter contents Introduction 70...
Страница 194: ...A Network Ports RJ 21X connector pin out mDSL DACS Administrators Reference Guide 192 Introduction...
Страница 195: ...193 Appendix B WAN Network Module connector pin out Chapter contents Introduction 194...
Страница 199: ...Introduction 197 DSL DACS Administrators Reference Guide B WAN Network Module connector pin out...
Страница 200: ...B WAN Network Module connector pin out DSL DACS Administrators Reference Guide 198 Introduction...