
21 • T1/E1 Link
mDSL DACS Administrators’ Reference Guide
166
WAN Circuit Configuration—Modify
Line Type (dsx1LineType) Type (dsx1LineType)
This variable indicates the type of DS1 Line implemented on this circuit. The type of circuit affects the num-
ber of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error
statistics. The values, in sequence, are:
•
other(1) —Link is disabled
•
dsx1ESF(2)—Extended Superframe DS1
•
dsx1D4(3)—AT&T D4 format DS1
•
dsx1E1(4)—Based on CCITT/ITU G.704 without CRC
•
dsx1E1-CRC(5)—Based on CCITT/ITU G.704 with CRC
Line Coding (dsx1LineCoding)
This variable describes the type of Zero Code Suppression used on the link, which in turn affects a number of
its characteristics.
•
dsx1JBZS(1)—Jammed Bit Zero Suppression, in which the AT&T specification of at least one pulse every
8 bit periods is literally implemented by forcing a pulse in bit 8 of each channel. Thus, only seven bits per
channel, or 1.344 Mbps, is available for data. This feature is not currently implemented.
•
dsx1B8ZS (2)—The use of a specified pattern of normal bits and bipolar violations which are used to
replace a sequence of eight zero bits. The most common coding for T1 circuits.
•
dsx1HDB3(3)—This line coding is used with most E1 circuits today.
•
dsx1ZBTSI(4)—May use
dsx1ZBTSI
, or Zero Byte Time Slot Interchange. This feature is not currently
implemented.
•
dsx1AMI(5)—Refers to a mode wherein no zero code suppression is present and the line encoding does not
solve the problem directly. In this application, the higher layer must provide data which meets or exceeds
the pulse density requirements, such as inverting HDLC data.
•
other(6)—This feature is not currently supported.
Receive Equalizer (linkRxEqualizer)
This variable determines the equalization used on the received signal. Long haul signals should have the equal-
ization set for more. Short haul signals require less equalization.
•
linkRxEqualizerOff(1)
•
linkRxEqualizerOn(2)
Line Build Out (linkLineBuildOut)
This variable is used in T1 applications to adjust the T1 pulse shape at the cross connect point. Select the pulse
strength needed to minimize distortion at the remote T1 receiver end. The default is
t1pulse0dB
, which
should be adequate for most situations.
•
triState(0)
•
e1pulse(1)
•
t1pulse0dB(2)—Strong pulse amplitude.
Содержание 3095
Страница 20: ...About this guide mDSL DACS Administrators Reference Guide 18...
Страница 24: ...1 Introduction mDSL DACS Administrators Reference Guide 22 Saving HTTP HTML Object Changes...
Страница 29: ...27 Chapter 3 Import Export Chapter contents Introduction 28 Export Configuration 28 Import Configuration 30...
Страница 40: ...5 System History mDSL DACS Administrators Reference Guide 38 mDSL History table...
Страница 50: ...6 Alarms mDSL DACS Administrators Reference Guide 48 Modify Alarms Configuring alarm severity levels...
Страница 56: ...7 DS0 Mapping mDSL DACS Administrators Reference Guide 54 Displaying the DS0 Mapping window...
Страница 96: ...11 Filter IP mDSL DACS Administrators Reference Guide 94 Defining a filter...
Страница 97: ...95 Chapter 12 Frame Relay Chapter contents Introduction 96...
Страница 122: ...15 TCP mDSL DACS Administrators Reference Guide 120 TCP Details...
Страница 126: ...16 UDP mDSL DACS Administrators Reference Guide 124 Introduction...
Страница 132: ...17 RIP Version 2 mDSL DACS Administrators Reference Guide 130 RIP Version 2 Statistics...
Страница 138: ...18 SNMP mDSL DACS Administrators Reference Guide 136 Out...
Страница 150: ...19 System mDSL DACS Administrators Reference Guide 148 System Packet Holding Message Blocks...
Страница 180: ...21 T1 E1 Link mDSL DACS Administrators Reference Guide 178 Far End Line Statistics Totals...
Страница 185: ...183 Chapter 23 About Chapter contents Introduction 184 Patton Electronics Company contact information 184...
Страница 190: ...24 License mDSL DACS Administrators Reference Guide 188 End User License Agreement...
Страница 191: ...189 Appendix A Network Ports RJ 21X connector pin out Chapter contents Introduction 70...
Страница 194: ...A Network Ports RJ 21X connector pin out mDSL DACS Administrators Reference Guide 192 Introduction...
Страница 195: ...193 Appendix B WAN Network Module connector pin out Chapter contents Introduction 194...
Страница 199: ...Introduction 197 DSL DACS Administrators Reference Guide B WAN Network Module connector pin out...
Страница 200: ...B WAN Network Module connector pin out DSL DACS Administrators Reference Guide 198 Introduction...