Line Status (dsx1LineStatus)
163
mDSL DACS Administrators’ Reference Guide
21 • T1/E1 Link
For D4 links, the Far End Alarm failure occurs when bit 6 of all channels has been zero for at least 335 ms. The
alarm is cleared when bit 6 of at least one channel is non-zero for a period
T
, where
T
is usually less than 1 sec-
ond and always less than 5 seconds. The Far End Alarm failure is not declared for D4 links when a Loss of Sig-
nal is detected.
For ESF links, the Far End Alarm failure is declared if the Yellow Alarm signal pattern occurs in at least 7 out of
10 contiguous 16-bit pattern intervals. The alarm is cleared when the Yellow Alarm signal pattern has not
occurred for 10 contiguous 16-bit signal pattern intervals.
For E1 links, the Far End Alarm failure is declared when bit 3 of time-slot zero is received set to 1 on two con-
secutive occasions. The Far End Alarm failure is cleared when bit 3 of time-slot zero is received set to zero.
Alarm Indication Signal (AIS) Failure
The Alarm Indication Signal failure is declared when an AIS defect is detected at the input and the AIS defect
still exists after the Loss Of Frame failure (which is caused by the unframed nature of the
all-ones
signal) is
declared. The AIS failure is cleared when the Loss Of Frame failure is cleared.
Loss Of Frame Failure
For T1 links, the Loss Of Frame failure is declared when an OOF or LOS defect has persisted for
T
seconds,
where 2
≤
T
≤
10. The Loss Of Frame failure is cleared when there have been no OOF or LOS defects during
a period
T
where 0
≤
T
≤
20. Many systems will perform
hit integration
within the period
T
before declaring or
clearing the failure (for more information, see TR 62411 [16]).
For E1 links, the Loss Of Frame Failure is declared when an OOF defect is detected.
Loss Of Signal Failure
For T1, the Loss Of Signal failure is declared upon observing 175 +/- 75 contiguous pulse positions with no
pulses of either positive or negative polarity. The LOS failure is cleared upon observing an average pulse density
of at least 12.5% over a period of 175 ±75 contiguous pulse positions, starting with the receipt of a pulse.
For E1 links, the Loss Of Signal failure is declared when greater than 10 consecutive zeroes are detected (see
O.162 Section 3.4.4).
Loopback Pseudo-Failure
The Loopback Pseudo-Failure is declared when the near end equipment has placed a loopback (of any kind) on
the DS1. This allows a management entity to determine from one object whether the DS1 can be considered
to be in service or not (from the point of view of the near end equipment).
TS16 Alarm Indication Signal Failure
For E1 links, the TS16 Alarm Indication Signal failure is declared when time-slot 16 is received as all ones for
all frames of two consecutive multiframes (see G.732 Section 4.2.6). This condition is never declared for T1.
Loss Of MultiFrame Failure
The Loss Of MultiFrame failure is declared when two consecutive multiframe alignment signals (bits 4 through 7
of TS16 of frame 0) have been received with an error. The Loss Of Multiframe failure is cleared when the first cor-
rect multiframe alignment signal is received. The Loss Of Multiframe failure can only be declared for E1 links
operating with G.732 [18] framing (sometimes called
Channel Associated Signalling
mode).
Содержание 3095
Страница 20: ...About this guide mDSL DACS Administrators Reference Guide 18...
Страница 24: ...1 Introduction mDSL DACS Administrators Reference Guide 22 Saving HTTP HTML Object Changes...
Страница 29: ...27 Chapter 3 Import Export Chapter contents Introduction 28 Export Configuration 28 Import Configuration 30...
Страница 40: ...5 System History mDSL DACS Administrators Reference Guide 38 mDSL History table...
Страница 50: ...6 Alarms mDSL DACS Administrators Reference Guide 48 Modify Alarms Configuring alarm severity levels...
Страница 56: ...7 DS0 Mapping mDSL DACS Administrators Reference Guide 54 Displaying the DS0 Mapping window...
Страница 96: ...11 Filter IP mDSL DACS Administrators Reference Guide 94 Defining a filter...
Страница 97: ...95 Chapter 12 Frame Relay Chapter contents Introduction 96...
Страница 122: ...15 TCP mDSL DACS Administrators Reference Guide 120 TCP Details...
Страница 126: ...16 UDP mDSL DACS Administrators Reference Guide 124 Introduction...
Страница 132: ...17 RIP Version 2 mDSL DACS Administrators Reference Guide 130 RIP Version 2 Statistics...
Страница 138: ...18 SNMP mDSL DACS Administrators Reference Guide 136 Out...
Страница 150: ...19 System mDSL DACS Administrators Reference Guide 148 System Packet Holding Message Blocks...
Страница 180: ...21 T1 E1 Link mDSL DACS Administrators Reference Guide 178 Far End Line Statistics Totals...
Страница 185: ...183 Chapter 23 About Chapter contents Introduction 184 Patton Electronics Company contact information 184...
Страница 190: ...24 License mDSL DACS Administrators Reference Guide 188 End User License Agreement...
Страница 191: ...189 Appendix A Network Ports RJ 21X connector pin out Chapter contents Introduction 70...
Страница 194: ...A Network Ports RJ 21X connector pin out mDSL DACS Administrators Reference Guide 192 Introduction...
Страница 195: ...193 Appendix B WAN Network Module connector pin out Chapter contents Introduction 194...
Страница 199: ...Introduction 197 DSL DACS Administrators Reference Guide B WAN Network Module connector pin out...
Страница 200: ...B WAN Network Module connector pin out DSL DACS Administrators Reference Guide 198 Introduction...