Coral Sea Vertical 6800
Page 2-10
Pre-installa
tion
13. Flow meter - FL 1003 4-40 gpm (15.1-151 lpm)
measures the combined rate of the backwash water
through the Media Filters.
K. ELECTRICAL CONTROLLER PANEL
1. Contactor, High Pressure Pump Motor Starter is rated
for a maximum of 10 horsepower.
1. Salinity Controller is the central point of connection
for all electrical lines in the System. The controller
monitors the salt content of the product water (by
means of the salinity probe), and signals the PVC
three-way diversion actuator valve, when potable
water is being produced. The PVC three-way
diversion actuator valve, motors, U.V. sterilizer, and
remote monitor are all directly connected to and
governed by the Salinity Controller.
Optional electrical equipment is also available such
as soft motor starters and disconnect switches.
Consult Sea Recovery’s Application Engineering
Department.
J. FRONT CONTROL PANEL
1. Pressure gauge - PI 1000 - 30 in. Hg to 70 psi (-1 to
4.8 bar) registers booster pump inlet vacuum suction
or pressure.
2. Pressure gauge -PI 1001 0 to 160 psi (0 to 11 bar)
registers booster pump outlet pressure, which is also
inlet pressure to the Media Filter.
3. & 4. Pressure gauges -PI 1002 0 to 60 psi (0 to 11
bar) registers combined Media Filter outlet pressures
as well as the 20 micron cartridge pre-fi lter inlet
pressures.
5. & 6. Pressure gauges - PI 1003 0 to 160 psi (0 to 11)
registers combined 20 micron cartridge pre-fi lter
outlet pressures as well as the 5 micron cartridge
pre-fi lter inlet pressures.
7. Pressure gauge - PI 1004 0 to 160 psi (0 to 11 bar)
registers combined 5 micron cartridge pre-fi lter outlet
pressure as well as the high pressure pump inlet
pressure.
8. Pressure gauge - PI 1005 0-2000 psi (0-138 bar)
registers outlet pressure from the high pressure
pump as well as the inlet pressure to the R.O.
membrane vessel assemblies.
9. Pressure gauge - PI 1006 0-2000 psi (0-138 bar)
registers outlet pressure from the R.O. membrane
vessel assemblies as well as the inlet pressure to the
back pressure regulator.
10. Pressure gauge - PI 1007 0-160 psi (0-11 bar)
registers the combined outlet pressure from the
product water port of the R.O. membrane vessels
(product water line pressure).
11. Pressure gauge - PI 1008 0-160 psi (0-11 bar)
registers the pressure present in the brine discharge
line.
12. Flow meter - FL 1001 10-80 gpm (37.8-302 lpm)
measures the rate of the feed water progress through
the System.
Coral Sea Owner's Manual
Содержание Coral Sea
Страница 3: ...SECTION 1 SYSTEM DESCRIPTION Coral Sea Owner s Manual...
Страница 14: ...SECTION 2 PRE INSTALLATION NOTES Coral Sea Owner s Manual...
Страница 25: ...SECTION 3 ELECTRICAL INFORMATION Coral Sea Owner s Manual...
Страница 28: ...SECTION 4 INSTALLATION REQUIREMENTS Coral Sea Owner s Manual...
Страница 34: ...Coral Sea Vertical 6800 Page 4 6 Installation This page is intentionally left blank Coral Sea Owner s Manual...
Страница 35: ...SECTION 5 OPERATIONS MANUAL Coral Sea Owner s Manual...
Страница 36: ...Operation THIS PAGE INTENTIONALLY LEFT BLANK Coral Sea Owner s Manual...
Страница 166: ...Intentionally Left Blank Coral Sea Owner s Manual...
Страница 167: ...SECTION 6 R O MEMBRANE INSTALL CARE Coral Sea Owner s Manual...
Страница 168: ...Coral Sea Vertical 6800 Page 6 ii R O MEMBRANE Page Intentionally Left Blank Coral Sea Owner s Manual...
Страница 193: ...SECTION 7 MAINTENANCE AND REPAIR Coral Sea Owner s Manual...
Страница 194: ...Maintenance Coral Sea Owner s Manual...
Страница 203: ...SECTION 8 COMPONENT USER MANUALS Coral Sea Owner s Manual...
Страница 204: ...Page Intentionally Left Blank Coral Sea Owner s Manual...
Страница 215: ...SECTION 9 DRAWING PULL OUTS Coral Sea Owner s Manual...
Страница 216: ...Page Left Intentionally Blank Coral Sea Owner s Manual...
Страница 247: ...SECTION 10 SPARE PARTS LIST Coral Sea Owner s Manual...