Media Filter Outlet Valve Did Not
Attempt To Close**
The control system commanded the media filter outlet
valve to close but the valve did not respond to the
command at all. Check that the valve is switch to
'Auto' and that all power wiring is free from breaks or
snags. Check 5 x 20mm fuses within the control panel
for failures (indicated by red light)
67
Media Filter Outlet Valve Failed To
Complete Close Motion**
The control system commanded the media filter outlet
valve to close. The valve responded to the command
but failed to close completely in the time allowed.
Probable cause of failure is either power loss to the
valve, or a worn and failing actuator. Check 5 x 20 mm
fuses within control panel for failures (indicated by red
light)
68
Media Filter Rinse Valve Position
Feedback Lost**
The control system has lost all position feedback from
the media filter inlet rinse. Check valve wiring for
breaks or snags, check 5 x 20mm fuses within the
control panel for failures (indicated by red light)
69
Media Filter Rinse Valve Did Not
Attempt To Open**
The control system commanded the media filter rinse
valve to open but the valve did not respond to the
command at all. Check that the valve is switch to
'Auto' and that all power wiring is free from breaks or
snags. Check 5 x 20mm fuses within the control panel
for failures (indicated by red light)
70
Media Filter Rinse Valve Failed To
Complete Open Motion**
The control system commanded the media filter rinse
valve to open. The valve responded to the command
but failed to open fully in the time allowed. Probable
cause of failure is either power loss to the valve, or a
worn and failing actuator. Check 5 x 20 mm fuses
within control panel for failures (indicated by red light)
71
Media Filter Rinse Valve Opening
Fault**
This fault indicator is usually raised along with either a
failure to respond to open command fault, or an open
command motion failed to complete.
72
Media Filter Rinse Valve Closing
Fault**
This fault indicator is usually raised along with either a
failure to respond to close command fault, or a close
command motion failed to complete.
Coral Sea Owner's Manual
Содержание Coral Sea
Страница 3: ...SECTION 1 SYSTEM DESCRIPTION Coral Sea Owner s Manual...
Страница 14: ...SECTION 2 PRE INSTALLATION NOTES Coral Sea Owner s Manual...
Страница 25: ...SECTION 3 ELECTRICAL INFORMATION Coral Sea Owner s Manual...
Страница 28: ...SECTION 4 INSTALLATION REQUIREMENTS Coral Sea Owner s Manual...
Страница 34: ...Coral Sea Vertical 6800 Page 4 6 Installation This page is intentionally left blank Coral Sea Owner s Manual...
Страница 35: ...SECTION 5 OPERATIONS MANUAL Coral Sea Owner s Manual...
Страница 36: ...Operation THIS PAGE INTENTIONALLY LEFT BLANK Coral Sea Owner s Manual...
Страница 166: ...Intentionally Left Blank Coral Sea Owner s Manual...
Страница 167: ...SECTION 6 R O MEMBRANE INSTALL CARE Coral Sea Owner s Manual...
Страница 168: ...Coral Sea Vertical 6800 Page 6 ii R O MEMBRANE Page Intentionally Left Blank Coral Sea Owner s Manual...
Страница 193: ...SECTION 7 MAINTENANCE AND REPAIR Coral Sea Owner s Manual...
Страница 194: ...Maintenance Coral Sea Owner s Manual...
Страница 203: ...SECTION 8 COMPONENT USER MANUALS Coral Sea Owner s Manual...
Страница 204: ...Page Intentionally Left Blank Coral Sea Owner s Manual...
Страница 215: ...SECTION 9 DRAWING PULL OUTS Coral Sea Owner s Manual...
Страница 216: ...Page Left Intentionally Blank Coral Sea Owner s Manual...
Страница 247: ...SECTION 10 SPARE PARTS LIST Coral Sea Owner s Manual...