© Panduit Corp. 2018
OPERATION MANUAL
ENGLISH
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
PA27647A01_05
Page: 15 of 64
12-2018
3. Is the filter element rating correct? (40 micron maximum)
4. Is the filter/regulator equivalent to recommended? (See Page 12.)
5. Are the quick-connect fittings equivalent to recommend? (See Page 12.)
6. Is the filter/regulator located as close to the dispenser as possible? (10' - 0" (3 m) maximum)
7. Is the dispenser placed or mounted in a convenient location? (Refer to the
Hose and Installation Tool
Assembly
Section on Page 15.)
8. Is the regulated airline pressure and flow to dispenser sufficient? (Refer to the
Air Supply
section on Page 12.)
7C: Hose and Installation Tool Assembly
1. Connect either end of the PHM Feeder Hose to the PDM4.0 Dispenser connection block (See Figs. 8 & 9). Align
the connectors and push the hose end onto the dispenser connection block until the latches engage. Always
position the dispenser in the work area so there are no severe bends or twists in the PHM Feeder Hose, thus
ensuring a minimum bend radius of 12” (0,3m).
Fig. 8
Fig. 9
PHM Feeder Hose
PDM4.0 Dispenser Connection Block
2.
Connect the other end of the feeder hose to the PAT installation tool in the same manner, see Fig. 10
Fig. 10
INSTALLATION TOOL
Tip Collector
Front & Rear Jaws
PHM Feeder Hose
Содержание PAT1.5M4.0
Страница 2: ......