© Panduit Corp. 2018
OPERATION MANUAL
ENGLISH
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
PA27647A01_05
Page: 57 of 64
12-2018
MESSAGE
POSSIBLE CAUSE
CORRECTIVE ACTION
ERROR 12
Tie stuck in tool
sensor
Cable tie has stopped in the tool
sensor area of tool.
1. Press “Silence” icon to silence the alarm.
2. Follow corrective action for "Blocked or dirty tool sensor"
error above.
ERROR 13
Detent sensor
blocked or dirty
Tip collector full. Detent sensor
blocked by detent cam, foreign
object, or detent sensor lens is
dirty.
1. Press “Silence” icon to silence the alarm.
2. Remove cable tie from jaw area of tool.
3. Press the "Back" icon and resume operation.
4. If message reappears, notify maintenance department.
ERROR 14
Internal regulator
incorrectly set, low
Internal regulator was adjusted in-
correctly, or the piston is not fully
shifting.
1. Press “Silence” icon to silence the alarm and resume
operation.
2. If message remains, system will not operate. Write down
message and notify maintenance department.
ERROR 15
Internal regulator
incorrectly set, high
Internal regulator was adjusted
incorrectly.
ERROR 16
Tie stuck in gripper
Excessive humidity or dry ties with
high tool tension
1. Press “Silence” icon to silence the alarm.
2. Lower the tension setting on the tool.
3. Pull trigger to complete cycle
4. Reset tension
ERROR 17
Full tip collector
Tip collector counter has reached
maximum number of tips
1. Press “Silence” icon to silence the alarm.
2. Remove tip collector and empty.
3. Re- attach the tip collector
4. Press “Back” to reset the internal counter
*If the cable tie does not come out freely, turn the dispenser "off" and then "on" again to reset the rotary receiver's position.
12B: Functional Message Troubleshooting
MESSAGE
POSSIBLE CAUSE
CORRECTIVE ACTION
No exit sensor
seen - service
tool soon
Cable tie in feeder hose when tool was
actuated or dispenser exit sensor is
not functioning properly.
1. Resume operation.
2. If the same error is repeated, the exit sensor lens may be
dirty, or it may not be functioning properly.
3. Clean the exit sensor lens (Refer to the
Cleaning the
Dispenser Exit Sensor Lens
section on Page 53).
4. If the same error is repeated, notify your maintenance
department.
Trigger
Malfunction
The trigger was held down or was
stuck when the dispenser was turned
“on”. This message will remain if the
trigger switch has malfunctioned.
1. The message will disappear when the trigger has been freed
or released.
2. If the message does not disappear, then the trigger is bad.
Contact your maintenance department to have the trigger
switch replaced.
Jaw sensor
error
Cable tie stopped in tool gears.
1. Press “Silence” icon to turn buzzer "off".
2. Remove the cable tie from the jaw area.
3. Press the "Continue" icon and resume operation.
Dispenser
Sensor
Sensor is not functioning correctly.
1. Press the “Back” icon and resume operation.
2. If the dame error is repeated, notify your maintenance
department.
Tie Sensor
See Page 50.
See Page 50