© Panduit Corp. 2018
OPERATION MANUAL
ENGLISH
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
PA27647A01_05
Page: 26 of 64
12-2018
MAINTENANCE > LOG
ID
CYCLES
SERIAL
DESCRIPTION
1 600 000 000
1234567
ERROR 1 > EMPTY TIE
2 500 000 000
1234567
ERROR 3 > LOW PRESSURE
3 400 000 000
1234567
ERROR 3 > LOW PRESSURE
4 300 000 000
1234567
ERROR 5> DISPENSER JAM
5 200 000 000
1234567
ERROR 5> DISPENSER JAM
PREVIOUS
NEXT
BACK
20
b) Press the
“Log"
icon to view total tie count, serial number and a description of errors. The
Dispenser stores up to 125 errors. Navigation thru the error log is made simple with the option to move
by using previous or next to jump by 5 errors. If an expanded performance record is required for
planned maintenance and system performance, actuation of the dispenser’s Data Interface option is
required. Contact your local Panduit Sales Representative for details on actuation.
Pressing the
"Back"
icon after reviewing the errors will return to the previous menu level.
c) Press the
"Pressure"
icon to view the line pressure before and during a cycle. Pressing this icon
will bring up the following display:
MAINTENANCE> LINE PRESSURE
PSI
BAR
BEFORE CYCLE
DURING CYCLE
BACK
18
The pressure measurement is in both BAR and PSI. Refer to
Air Supply
section on Page 12 for the
recommended operating pressure for optimum performance. Pressing the
"Back"
icon after reviewing
the pressures will return to the previous menu level.
d) Press the
“Sensor”
icon to find out the state of each sensor in the system. Pressing this
icon will bring up the following display: