© Panduit Corp. 2018
OPERATION MANUAL
ENGLISH
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
PA27647A01_05
Page: 30 of 64
12-2018
ERROR > HELP
GUIDE TIES IN, PRESS LOAD
AIR BURST
LOAD
MAINTENANCE
PREVIOUS
BACK
32
Help Screen Step 2
POSSIBLE CAUSE:
This usually occurs if the dispenser has run out of cable ties, or if a cable tie is prevented
from leaving the dispenser.
CORRECTIVE ACTION:
Press the
“Silence” icon
to turn the alarm signal "off". If the reel is empty, refer to the
Reloading Procedure
section on Page 19. If help is required, press the
"Help"
icon and perform the standard
reloading procedure (Refer to the
Reloading Procedure
section on Page 19).
Pressing the
"Back"
will return to the previous menu level.
If “
Out of ties or tie in dispenser”
message appears, and it is apparent that the reel is not empty, then the tool
was cycled without enough cable ties loaded, or a cable tie was prevented from leaving the dispenser. A cable tie
will remain in the dispenser due to little or no air pressure, or an obstruction. In all cases, disconnect the air hose
and feeder hose from the dispenser. If a cable tie is in the connector block, and it can be removed; do so. If a
cable tie is not seen, contact your maintenance department to prevent further complications. After the cable tie is
removed, reconnect the air hose and the feeder hose to the dispenser. Press the
"Back"
icon to bring up the
"Ready" display. Press the
"Load"
icon to load next cable tie into position in the dispenser. Continue system
operation.
PREVENTION:
To prevent this problem from recurring, verify that the line air pressure is between 65 and 85
PSIG (4,5 and 5,8 bar), with a maximum 10 PSI (0,7 bar) drop.
ERROR 2 - Door is open, no tie loaded
ERROR 2 > DOOR OPEN
NO TIE LOADED
AIR BURST
LOAD
MAINTENANCE
SILENCE
HELP
BACK
34
Error Screen
POSSIBLE CAUSE:
This message will be displayed if the cover was open and the "Load" icon was pressed or
the tool was cycled.
Содержание PAT1.5M4.0
Страница 2: ......