13: CABLE TIE CONDITION FACTORS
13A: Cable Tie Condition Factors
INCORRECT CABLE TIE
CUT-OFF
(Long cut-off / tail)
CORRECT CABLE TIE
CUT-OFF
CABLE TIE DETACHES
FROM BUNDLE
• Cable ties are too moist
(due to high humidity)
-
Turn down tension until correct cut-off
occurs.
• Cable ties are too brittle
(due to dry conditions)
-
Take new reel of ties out of
original bag.
-
Place new ties on PDM4.0.
-
Place used reel in bag with
damp paper towel or sponge to
recondition.
14: WEB Browser Interface
14A: REQUIREMENTS
The PAT SYSTEM web server has been tested with Microsoft Internet Explorer 11 running on Windows 7
operating system. Other web browsers and operating systems may work as well, but proper operation is not
guaranteed. The appearance of the WBI can be adjusted through the web browser settings.
14B: STATUS VIA PC
Status information for the PAT SYSTEM may be accessed by running a web browser on a PC that is connected to
the same network to which the PAT SYSTEM is connected. The Network is accessed via the Ethernet port located
on the back of the dispenser. The connection is a standard RJ-45 type receptacle. This port should be connected
to a router running a DHCP server. The PAT SYSTEM will be assigned an IP address by the DHCP server running
on the network. The network can be configured to assign either a static or dynamic IP address to the PAT SYSTEM.
Consult with the network administrator as to how to determine the assigned IP address.
14C: CONNECTING TO THE PAT SYSTEM
Within the web browser address bar type “http://nnn.nnn.nnn.nnn” where nnn.nnn.nnn.nnn is the IP address
assigned to the PAT SYSTEM unit by the network.