© Panduit Corp. 2018
OPERATION MANUAL
ENGLISH
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
PA27647A01_05
Page: 49 of 64
12-2018
POSSIBLE CAUSE:
This message will appear if the trigger is held down or stuck when the dispenser is turned
"on". This message will also appear if the switch has malfunctioned.
CORRECTIVE ACTION:
When this occurs, the message will disappear when the trigger has been freed or
released. If the
"Trigger is stuck or broken”
message does not disappear, then the trigger is bad. Contact your
maintenance department to have the trigger replaced.
PREVENTION:
To prevent this problem from recurring, do not press or hold down the trigger when turning the
dispenser power
“on”
.
Problem 3 Jaw sensor error
PROBLEM 3 > JAW SENSOR
SENSOR ERROR. SEE MAINTENANCE
BACK
5
POSSIBLE CAUSE:
A buildup of debris in the tool gears caused by not emptying the tip collector often enough.
CORRECTIVE ACTION:
Press the
“Silence”
icon to turn the alarm signal "off". Remove the cable tie and any
obstruction from the jaw and exit areas of the tool, and empty the tip collector. Press the continue icon and resume
operation. If the tool does not operate contact maintenance.
PREVENTION:
Always empty the tip collector before it is full (no more than 300 cycles). Keeping the tip collector
clear will allow the cable ties an area to exit the tool. The tool should also be cleaned periodically by your
maintenance department.
Problem 4 - Dispenser sensor error
PROBLEM 4 > NO DISPENSER SENSOR
SENSOR ERROR. SEE MAINTENANCE
BACK
6
POSSIBLE CAUSE:
A buildup of debris in the dispenser rotary caused by not cleaning the dispenser sensor
often enough.
CORRECTIVE ACTION:
Press the
“Back”
icon
continue and resume operation. If the dispenser does not
operate contact maintenance.
Содержание PAT1.5M4.0
Страница 2: ......