ERROR > HELP
PRESS AIR BURST, REMOVE TIE
AIR BURST
LOAD
MAINTENANCE
PREVIOUS
BACK
57
Help Screen Step 3
CORRECTIVE ACTION:
Press the
“Silence” icon
to turn the alarm signal "off". Disconnect feeder hose from
dispenser. Look for cable tie in dispenser connector block and remove cable tie, if present. Reconnect feeder
hose, and resume operation. If the cable tie is not found, reconnect the feeder hose. Straighten the feeder hose
to eliminate any bends or twists and point the tool away from yourself and others. Press the
"Air burst"
icon to
provide a burst of air to dislodge and advance the cable tie to the jaw area of the tool. The
"Air Burst"
icon can
be pressed again if the cable tie does not advance to the jaw area. When the cable tie is advanced to the tool
jaw area, the "Tie in tool" message will appear and the buzzer will sound. Press the
“Silence” icon
to turn the
alarm signal "off". Remove the cable tie from the jaw area. Press the
"Load"
icon to load cable ties into the
dispenser and continue operation. If the cable tie does not advance to the tool jaw area after depressing the
"Air
Burst"
icon several times, replace the feeder hose with another and notify your maintenance department.
Pressing the
"Back"
will return to the previous menu level.
PREVENTION:
If this same error is repeated, the dispenser exit sensor lens may be cleaned with a cotton swab
dampened with isopropyl alcohol. Disconnect the feeder hose from the dispenser and insert the dampened end
of the cotton swab into the dispenser transfer tube about 1.5" (38 mm). Gently move the cotton swab in and out,
against the top and bottom walls of the transfer tube, to clean the sensor.