ERROR 4 - Check for high air pressure
ERROR 4 > HIGH PRESSURE
DECREASE AIR PRESSURE
AIR BURST
LOAD
MAINTENANCE
SILENCE
HELP
BACK
39
Error Screen
POSSIBLE CAUSE:
This message will be displayed if the incoming air pressure is too high.
CORRECTIVE ACTION:
Press the
“Silence” icon
to turn the alarm signal "off".
MAINTENANCE> PRESSURE
PSI
BAR
BEFORE CYCLE
DURING CYCLE
BACK
18
Decrease the air pressure to below 85 PSIG (5,8 bar). Pressing the
"Back"
will return to the previous menu level.
PREVENTION:
To prevent this problem from recurring, verify that the air pressure is between 65 and 85 PSIG (4,5
and 5,8 bar).