ERROR > HELP
REMOVE AND EMPTY TIP COLLECTOR
MAINTENANCE
PREVIOUS
NEXT
BACK
77
Help Screen Step 1
ERROR > HELP
RE-ATTACH TIP COLLECTOR
AIR BURST
LOAD
MAINTENANCE
PREVIOUS
BACK
78
Help Screen Step 2
Remove the cable tie from the jaw area of the tool and empty the tip collector. Press the
"Back"
icon and resume
operation. If the error message appears again, notify your maintenance department.
PREVENTION:
Always empty the tip collector before it is full (no more than 300 cycles). This will prevent debris
from re-entering the tool because the tip collector is too full. Keeping the tip collector clear will allow the cable ties
an area to exit the tool. The tool should also be cleaned periodically by your maintenance department.
ERROR 14 - Internal regulator incorrectly set, low
ERROR 14 > INTERNAL REG.
INCORRECTLY SET, LOW
AIR BURST
LOAD
MAINTENANCE
SILENCE
HELP
BACK
80
Error Screen