© Panduit Corp. 2018
OPERATION MANUAL
ENGLISH
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
PA27647A01_05
Page: 14 of 64
12-2018
Mount the carrier strip scrap bin (See on the left side of the dispenser by positioning the tab slots concentric over
the captive fastener on the dispenser. Next, attach the Reel Mount Assembly to the back of the dispenser (with
reel axle facing the front of the dispenser) by mounting the reel mount assembly on the dispenser using (2) M5 X
0.8mm X 25mm SHCS (provided), see Fig. 7 below. Tighten the cap screws to fasten the reel mount in position.
Fig. 7
NOTE:
The XMR Reel Mount Assembly can be mounted to the left or right side of dispenser, as shown.
Fig. 7A
Fig. 7B
7B: Pneumatic System Connection
For Panduit recommended air hose and filter/regulator parts, see Section
2D: Additional Components
on Page 7.
1. Connect the female quick disconnect end of the air hose and filter/regulator assembly to the male air inlet on
the back of the dispenser (See Fig. 2 on Page 5).
2. Connect the filter/regulator to the main (NON-LUBRICATED) air supply and set the filter regulator at 65-85
PSIG for optimum performance (Refer to the
Air Supply
section on Page 12).
3. Verify installation by reviewing the
Installation Checklist
section below.
Installation Checklist
1.
Have you made sure that the air supply is NON-LUBRICATED (from any source)?
2. Is the main air supply hose to the dispenser clean and sized properly? (3/8" inside diameter minimum, 10'-0"
(3 m) length maximum from filter/regulator to dispenser)
Содержание PAT1.5M4.0
Страница 2: ......