© Panduit Corp. 2018
OPERATION MANUAL
ENGLISH
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
PA27647A01_05
Page: 42 of 64
12-2018
area, the "Tie in tool" message will appear and the buzzer will sound. Press the
“Silence” icon
to turn the alarm
signal "off". Remove the cable tie from the jaw area and then press the
"Back"
icon. Press the
"Load"
icon to
load one cable tie into the dispenser and continue operation. If the cable tie does not advance to the tool jaw area
after depressing the
"Air Burst"
icon several times, replace the feeder hose with another and notify your
maintenance department.
PREVENTION:
If this same error is repeated, the dispenser exit sensor lens may be cleaned with a cotton swab
dampened with isopropyl alcohol. Disconnect the feeder hose from the dispenser and insert the dampened end of
the cotton swab into the end of the strap tube about 1.5" (38 mm). Gently move the cotton swab in and out, against
the top and bottom walls of the transfer tube, to clean the sensor.
ERROR 12 - Tie stuck in tool sensor
ERROR 12 > TIE STUCK
TOOL SENSOR OBSTRUCTED
AIR BURST
LOAD
MAINTENANCE
SILENCE
HELP
BACK
70
Error Screen
ERROR > HELP
DETACH TOOL, REMOVE DEBRIS
MAINTENANCE
PREVIOUS
NEXT
BACK
71
Help Screen Step 1
ERROR > HELP
RE-ATTACH TOOL TO HOSE
MAINTENANCE
PREVIOUS
NEXT
BACK
72
Содержание PAT1.5M4.0
Страница 2: ......