© Panduit Corp. 2018
OPERATION MANUAL
ENGLISH
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
PA27647A01_05
Page: 36 of 64
12-2018
ERROR 8 - Blocked hose - failed back pressure test
ERROR 8 > BLOCKED HOSE
FAILED BACK PRESS. TEST
AIR BURST
LOAD
MAINTENANCE
SILENCE
HELP
BACK
50
Error Screen
ERROR > HELP
CHECK HOSE FOR BENDS
MAINTENANCE
PREVIOUS
NEXT
BACK
51
Help Screen Step 1
ERROR > HELP
STRAIGHTEN, PRESS AIR BURST
AIR BURST
LOAD
MAINTENANCE
PREVIOUS
NEXT
BACK
52
Help Screen Step 2
POSSIBLE CAUSE:
The tool was actuated while there was still a cable tie or ties in the PHM Feeder Hose.
CORRECTIVE ACTION:
Press the
“Silence” icon
to turn the alarm signal "off". To clear the cable ties from the
feeder hose, straighten the hose to eliminate any bends or twists and point the tool away from yourself and others.
Press the
"Air burst"
icon to provide a burst of air to dislodge and advance the cable tie to the jaw area of the tool.
The
"Air Burst"
icon can be pressed again if the cable tie does not advance to the jaw area. When the cable tie
is advanced to the tool jaw area, the "Tie in tool" message will appear and the buzzer will sound. Press the
“Silence” icon
to turn the alarm signal "off". Press the
"Load"
icon to load cable ties into the dispenser and
continue operation. If the cable tie does not advance to the tool jaw area after depressing the
"Air Burst"
icon
several times, replace the feeder hose with another and notify your maintenance department.