PREVENTION:
The dispenser must be cleaned periodically by your maintenance department.
Problem 5 – Tie sensor error
PROBLEM 5 > NO TIE SENSOR SEEN
SENSOR ERROR. SEE MAINTENANCE
BACK
7
POSSIBLE CAUSE:
A buildup of debris in the dispenser rotary caused by not cleaning the tie sensor often
enough.
CORRECTIVE ACTION:
Press the
“Back”
icon continue and resume operation. If the dispenser does not
operate contact maintenance.
PREVENTION:
The dispenser must be cleaned periodically by your maintenance department.
9D: Status Messages
Status messages are displayed as the dispenser performs self-diagnoses. No action is required on the part of
the operator other than notifying the maintenance department of the status message.
STATUS 1 - Calibrate line pressure sensor
STATUS 2 - Calibrate back pressure sensor
STATUS 3 - Reset EEPROM
STATUS 4 - Reset dispenser RAM
STATUS 5 - Reset tool RAM