72
Chapter 3
Cable Connection
Cautions
Process and tighten the wires as follows:
Lead wire
Loosens
Tightens
A
<Dimension A>
S-LINK V
terminal block connector side : 7mm
DeviceNet terminal block connector side: 7mm
<Tightening torque>
S-LINK V
terminal block connector side : 0.5N·m or less
DeviceNet terminal block connector side: 0.6N·m or less
Recommended tool: Small-sized flathead screwdriver
S-LINK V
terminal block connector side:
Width = 3.8mm or less, thickness = 0.7mm or less
DeviceNet terminal block connector side:
Width = 4mm or less, thickness = 0.7mm or less
Wire processing dimension
●
Take care that wrong wiring will damage the product.
●
Do not short-circuit ‘0V’ and ‘G’ on the
S-LINK V
terminal block connector side.
● A large current may flow through the external power supply input, depending on the load. Use wires having
sufficient current capacity. Further, when supplying power to the load from
SL-VGU1-D
, make sure not to ex-
ceed the allowable through current.
● Tighten the screws of the flange also, so that the terminal block on the
S-LINK V
terminal block connector
side does not come out. The tightening torque should be 0.5N·m, or less.
●
Do not apply solder, etc., on the tips of the wires to be connected to the terminal block. This can cause loos-
ening of the screws, resulting in wire disconnection.
Содержание SL-VGU1-C
Страница 2: ...2 ...
Страница 5: ...5 Before Using This System ...
Страница 11: ...11 Chapter 1 Designing System ...
Страница 20: ...20 Chapter 1 MEMO ...
Страница 21: ...21 Chapter 2 SL VGU1 C Gateway Controller for CC Link ...
Страница 64: ...64 Chapter 2 MEMO ...
Страница 65: ...65 Chapter 3 SL VGU1 D Gateway Controller for Devicenet ...
Страница 94: ...94 Chapter 3 MEMO ...