17
Chapter 1
Transmission Delay Time
Operation at power-on
<Table 3 Time required for transmission check at starting controller>
Number of
I/O control
points
Time required for transmission check at starting controller
(ms)
A mode
B mode
C mode
32
69.5
134.3
422.1
64
82.6
186.8
632.2
96
100.4
258.1
917.5
128
123.0
348.3
1278.1
160
150.2
457.2
1713.9
192
182.2
585.0
2225.0
224
218.8
731.6
2811.4
256
260.2
897.0
3473.0
288
306.2
1081.2
4209.9
320
357.0
1284.3
5022.1
352
412.4
1506.1
5909.5
384
472.6
1746.8
6872.2
416
537.5
2006.3
7910.1
448
607.1
2284.6
9023.4
480
681.3
2581.7
10211.8
512
760.3
2897.6
11475.6
Displays 'rdy' till here.
● BUSY flag at normal starting
OFF
ON
● BUSY flag on buffer memory in upper network master
(6. Transmisison check > 3. Connection to upper network)
● BUSY flag on buffer memory in upper network master
(6. Transmission check < 3. Connection to upper network)
OFF
ON
OFF
ON
S-LINK V
gateway
controller
2. Setup for connection to upper network
5. Upper network
transmission
time
4. Data I/O with upper
network max. 1
refresh time
3. Connection to
upper network (Note)
S-LINK V
transmission
start
8. Upper network
transmission time
7. Data I/O with
upper network
Max. 1 refresh time
Power-on
6. Transmission check
1. Time required for power-on
(Depends on the supplied power)
Note: The time required for connection to the upper network depends on the use conditions.
Error signal outputting delay time
<Table 4 Time required for error check (errors 3, 4, and 5) >
Number of I/O
control points
Time required for error check (errors 3, 4, and 5) (ms)
A mode
B mode
C mode
32
43.5
174.0
695.8
64
93.4
373.6
1494.3
96
162.1
648.4
2593.8
128
249.6
998.6
3994.4
160
356.0
1424.0
5696.0
192
481.2
1924.7
7698.7
224
625.2
2500.6
10002.4
256
788.0
3151.8
12607.2
288
969.6
3878.3
15513.1
320
1170.0
4680.0
18720.0
352
1389.2
5557.0
22228.0
384
1627.3
6509.2
26037.0
416
1884.2
7536.8
30147.1
448
2159.9
8639.6
34558.2
480
2454.4
9817.6
39270.4
512
2767.7
11070.9
44283.6
<Table 5 Time required for error check (errors 1 and 2) >
Time required for error check (errors 1 and 2) (ms)
A mode
B mode
C mode
1.33
5.32
21.28
Occurrence of error
1. Error check
Error output
3. Output
0.5ms
2. Output to upper network
Max. 1 refresh time
Data read-out
on master side
S-LINK V
gateway
controller
4. Upper network
transmission
time
● Error output of gateway controller
OFF
ON
● Outputting error condition and error flag to buffer memory
in upper network master
OFF
ON
●
Error output delay time (1 + 3)
1 (From Table 4 or Table 5) + 3 (0.5ms)
●
Outputting error condition and error flag to buffer memory in upper network master transmission time
(1 + 2 + 3)
1 (From Table 4 or Table 5) + 2 (From Table 2) + 3 (Depending on upper network form)
Содержание SL-VGU1-C
Страница 2: ...2 ...
Страница 5: ...5 Before Using This System ...
Страница 11: ...11 Chapter 1 Designing System ...
Страница 20: ...20 Chapter 1 MEMO ...
Страница 21: ...21 Chapter 2 SL VGU1 C Gateway Controller for CC Link ...
Страница 64: ...64 Chapter 2 MEMO ...
Страница 65: ...65 Chapter 3 SL VGU1 D Gateway Controller for Devicenet ...
Страница 94: ...94 Chapter 3 MEMO ...