© Panasonic Industrial Devices SUNX Co., Ltd. 2016
40
Functions
[No.2: Parallel muting control]
Logic diagram
IN1
IN3
IN5
IN7
IN2
IN4
IN6
IN8
OUT1
OUT3
OUT2
OUT4
2NC
PNP semicon-
ductor input × 2
(equivalence)
Muting input
(equivalence)
Override input
AND
P-MUTE
Description of settings
Input
IN1 / IN2
2NC contact input
IN5 / IN6
Muting input (equivalence)
IN3 / IN4
PNP semiconductor input × 2
(equivalence)
IN7 / IN8
Override input
Control
output
OUT1 / 2
Interlock
Overall reset
OFF delay
0 sec. (Note 1)
OUT3 / 4
Interlock
Overall reset
OFF delay
0 sec. (Note 2)
Auxiliary
output
AUX1
Negative logic of OUT 1 / 2
AUX3
Reset trigger
AUX2
Negative logic of OUT 3 / 4
AUX4
Lockout
Notes: 1) Fixed at 0 sec.
2) Time can be selected using this device. For details, refer to “
<Timing chart>
●
When auto reset is set
IN1
IN3
IN5
IN7
IN2
IN4
IN6
IN8
T1
T3
T5
T7
T2
T4
T6
T8
OUT1/2
OUT3/4
Closed
Closed
Closed
Closed
ON
ON
ON
ON
ON
ON
ON
ON
Open
Open
Open
Open
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
100ms or less
100ms or less
100ms or less
0.05 sec. or less
0.05 sec. or less
Allowable tolerance of 0.03 to 3 sec.
Allowable tolerance of 0.03 to 3 sec.
10ms or less
10ms or less
10ms or less
10ms or less
3 sec. + 0.05 sec. or less
Muting status
Override status
10ms or less
1 sec. or less
MUTE
OVERRIDE
Note: Regarding the muting / override settings, refer to the factory default settings shown in “