Setting of Logics and OFF Delay Time
Step Status of indicators and switches
Description
22
The No. for OFF delay time is displayed in the 7-segment indicator (red).
• When the selected logic and OFF delay time are confirmed, hold down the
rotary switch to proceed to Step 24.
•
If either or both of the logic or OFF delay time differ from those selected,
rotate the rotary switch.
23
In the 7-segment indicator (red), “
” indicating “Back” is displayed.
The logic selection indicator (orange) and delay selection indicator (orange)
light up.
Pressing the rotary switch returns to Step 13.
Select logic and OFF delay time again.
24
Holding down the rotary switch changes the display to that shown in the il-
lustration at left.
In the 7-segment indicator (red), “
” indicating “OK” is displayed.
The logic selection indicator (orange) and delay selection indicator (orange)
blink.
Transition to “Write / confirm operation setting.”
The logic and OFF delay time set in this device have been changed.
Releasing the hand from the rotary switch proceeds to the next step.
25
After the end of write operation, logic No. and No. for OFF delay time are
alternately displayed in the 7-segment indicator (red).
A logic No. is shown in the illustration at left.
Logic selection indicator (orange) lights up.
As an example, “ ” is selected.
26
No. for OFF delay time is shown in the illustration at left.
Delay selection indicator (orange) lights up.
As an example, “ ” is selected.
After confirming operation setting, press the rotary switch.
27
Transition to “Quit setting mode.”