Wiring
<Output waveform [control output ON]>
When control output is turned ON, this device performs self-diagnosis of the output circuit.
The output is turned into OFF status periodically. (Refer to the figure below.)
When the OFF signal is fed back, this device judges the output circuit as normal.
When the OFF signal is not fed back, this device judges either the output circuit or wiring as er-
ror, and the control output maintains OFF status.
CAUTION
Perform the wiring with paying attention to the input response time of the machine to be connect-
ed to this device, since the OFF signal of this device might cause malfunction.
<Timing chart>
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Control output 1
(OUT1)
Control output 1
(OUT2)
Control output 2
(OUT3)
Control output 2
(OUT4)
Approx. 200μs
Approx. 200μs
Approx. 200μs
Approx. 200μs
Approx. 4.5ms
Approx. 4.5ms
Approx. 18ms
Approx. 4.5ms