Functions
3-12 Logic Settings by Software Tool
The software tool is available to change the settings of the following items. When logics are set,
control output 1 / 2 maintains OFF status. For details, refer to “
.”
<Setting item>
●
Input mode
●
Logic setting
●
Output mode (OFF delay, reset)
●
Auxiliary output mode
<Detailed setting item>
●
Input mismatch allowable time
● Input filter time
●
ON delay time
●
Allowable time difference in muting input
●
Muting duration
●
Exit-only muting time
●
Muting input condition
●
Override duration
●
MODBUS (RS-485) communication conditions (Baud rate, parity bit presence, parity bit type,
stop bit, and communication address)
Item
Setting range
Factory default (Note 1)
Input mismatch allowable time
0 (unlimited) to 60 sec. (in units of 0.01 sec.) 1 sec.
Input filter time
ON - OFF
0 to 1 sec. (in units of 0.01 sec.)
0 sec.
OFF - ON
ON delay time
0 to 5,940 sec. (in units of 0.1 sec.)
0 sec.
OFF delay time
0 to 60 sec. (in units of 0.1 sec.)
0 sec.
Allowable time
difference in
muting input
Parallel muting
1 to 10 sec. (in units of 1 sec.)
3 sec.
Sequential muting
0 (unlimited) to 288,000 sec. (in units of 1 sec.) 288,000 sec.
Muting duration
0 (unlimited) to 5,940 sec. (in units of 1 sec.) 5,940 sec.
Exit-only muting time (Note 2)
1 to 4 sec. (in units of 0.1 sec.)
0 sec.
Muting input condition
No priority/A priority/B (D) Priority
No priority
Override duration
1 to 600 sec. (in units of 1 sec.)
60 sec.
RS-485
communication
condition
Baud rate
9,600 bps to 115,200 bps
9,600 bps
Parity bit presence
Without / With
With
Parity bit type
Odd / even
Odd
Stop bit
1 bit / 2 bits
1 bit
Communication address 1 to 247
1
Notes: 1) Preset logic is fixed.
2) This setting in only for parallel muting.
Factory settings of customizable logics are invalid.