© Panasonic Industrial Devices SUNX Co., Ltd. 2016
98
Select Control
5-12 Select Control
Selectable control in control block 1 / 2 / 3
■ AND
“AND” of inputs connected to the control block is output.
Two or more inputs are connected.
The input blocks in which muting input (equ.), muting input (dif.),
override, key selector or test has been set cannot be connected.
■ OR
“OR” of inputs connected to the control block is output.
■ No logic
Selected when the control block is unused.
Selectable control only in control block 1
■ Parallel muting
Used when “Parallel muting” is performed.
In the connected muting input block, the IN with the smaller number is set as muting input A,
and the IN with the larger number is set as muting input B.
If input block 3 is set and connected as a muting input, IN5 becomes muting input A and IN6 be-
comes muting input B.
■ Sequential muting
Used when “Sequential muting” is performed.
In the two connected muting input blocks, INs are set as muting input A, muting input B, muting
input C and muting input D in the ascending order of the IN number.
If input blocks 2 and 3 are set and connected as muting inputs, IN3 becomes muting input A,
IN4 becomes muting input B, IN5 becomes muting input C, and IN6 becomes muting input D.
When “Sequential muting” is selected, both “Muting input (equ.)” and “Muting input (dif.)” cannot
be used for input block at a time.