© Panasonic Industrial Devices SUNX Co., Ltd. 2016
27
Functions
3-4 Interlock (Reset)
CAUTION
When the safety input condition of this device is satisfied, the control outputs turned into ON sta
-
tus in the case of auto reset setting. To prevent unexpected startup of the machine, secure safety
for the overall system.
The reset function of this device is set by selection of preset logic and wiring.
The software tool is available for selecting the overall reset or partial reset. For partial reset,
manual reset or auto reset is selectable.
3-4-1 Overall Reset
Overall reset: preset logic No.1, 2, 3, 6, 7, and 8
The outputs of two systems of this device are reset by one operation.
● Manual reset : Momentary type switch is connected to between INT11 and INT12.
Resetting operation can be performed by switching the switch contact from
“Close” to “Open.”
● Auto reset : INT21-INT22 is short-circuited.
If between INT21 and INT22 is not short-circuited when power is turned ON, manual reset is
automatically selected.
<Overall reset (manual start)>
INT11
INT21
INT12
INT22
With external device monitor
Without external device monitor
INT11
INT21
INT12
INT22
<Overall reset (auto start)>
INT11
INT21
INT12
INT22
With external device monitor
Without external device monitor
INT11
INT21
INT12
INT22