© Panasonic Industrial Devices SUNX Co., Ltd. 2016
43
Functions
[No.5. Partial stop control 2]
Logic diagram
IN1
IN3
IN5
IN7
IN2
IN4
IN6
IN8
OUT1
OUT3
OUT2
OUT4
2NC
2NC
2NC
2NC
AND
AND
Description of settings
Input
IN1 / IN2
2NC contact input
IN5 / IN6
2NC contact input
IN3 / IN4
2NC contact input
IN7 / IN8
2NC contact input
Control
output
OUT1 / 2
Interlock
Partial reset (manual start)
OFF delay
0 sec. (Note 1)
OUT3 / 4
Interlock
Partial reset (manual start)
OFF delay
0 sec. (Note 2)
Auxiliary
output
AUX1
Negative logic of OUT 1 / 2
AUX3
Reset trigger
AUX2
Negative logic of OUT 3 / 4
AUX4
Lockout
Notes: 1) Fixed at 0 sec.
2) Time can be selected using this device. For details, refer to “
<Timing chart>
●
Manual reset (standard setting)
IN1
IN3
IN5
IN7
IN2
IN4
IN6
IN8
T1
T3
T5
T7
T2
T4
T6
T8
OUT1/2
OUT3/4
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
ON
ON
Open
Open
Open
Open
Open
Open
Open
Open
Open
Open
OFF
OFF
100ms or less
100ms or less
100ms or less
100ms or less
100ms or less
150ms to 4 sec.
150ms to 4 sec.
150ms to 4 sec.
150ms to 4 sec.
150ms to 4 sec.
10ms or less
10ms or less
10ms or less
10ms or less
INT11/12 (Reset)
INT21/22 (Reset)