Preparation for Logic Setting
4-2 Preparation for Logic Setting
Preset logic can be set by using this device and power supply only. At the time of setting, devic-
es do not have to be connected to the input section or output section.
Connect power supplies (24V DC and 0V) to the terminal block for internal power supply and
the terminal block for external power supply in this device.
If power is supplied to either one of them, this device will not operate.
4-2-1 Turning ON the Power
Confirm that the mode selector switch is turned to the “RUN” side (left side: factory setting) and
then turn ON the power. The diagnosis function of this device carries out initial diagnosis, turn-
ing ON and OFF the indicators one by one.
After the end of initial diagnosis, the operation indicator (green) lights up.
If a terminal block is connected only to the power supply, auxiliary output indicator 1 / 2 / 4 (or-
ange) and interlock indicator 1 / 2 (yellow) light up.
The other indicators turn OFF.
Pressing the rotary switch displays “ ” (factory setting) in the 7-segment indicator (red), turning
ON the logic selection indicator (orange).
4-2-2 Portions Used in Settings
The following indicators and switches are used for preset logic settings.
●
7-segment indicator (Red)
●
Logic selection indicator (Orange)
●
Delay selection indicator (Orange)
●
Password selection indicator (Orange)
●
Operation indicator (Green)
●
Setting indicator (Orange)
●
Rotary switch
●
Mode selector switch
7-segment indicator (Red)
Logic selection indicator (Orange)
Rotary switch
Mode selector switch
Operation indicator (Green)
Setting indicator (Orange)
Delay selection indicator (Orange)
Password selection indicator (Orange)