Operation in RUN Mode and the Display
4-3 Operation in RUN Mode and the Display
4-3-1 Operation and Display During Normal Operation
Step Status of indicators and switches
Description
1
Mode selector switch: RUN side
Operation indicator (green): Lights up
The power saving function of this device turns OFF the 7-segment indicator
(red) 3 sec. after power ON, the end of initial diagnosis, or final operation.
2
Press the rotary switch.
The logic No. currently set is displayed in the 7-segment indicator (red).
Logic selection indicator (orange) lights up.
“
: Overall stop control” is set at factory.
3
Rotate the rotary switch.
The currently set No. for OFF delay time is displayed in the 7-segment indi-
cator (red).
Delay selection indicator (orange) lights up.
“
: 0 sec.” is set at factory.
Rotating the rotary switch returns to No.1.
4
Logic No. 0 is customizable logic.
To use customizable logic, this device must be connected to a PC to make
settings by a software tool.
Refer to “
”.
5
Selecting logic No. 0 always displays “ ” in the 7-segment indicator (red) as
the OFF delay time.