© Panasonic Industrial Devices SUNX Co., Ltd. 2016
26
Functions
3-2 Control Output
This device is equipped with two independent systems (4 outputs = 2 systems × duplication) for
control outputs (PNP semiconductor outputs).
● Control output 1: OUT1 / OUT2
● Control output 2: OUT3 / OUT4
• When safe: ON status
• When not safe / When locked out: OFF status
In the same system, two outputs perform the same operation.
3-2-1 Response Time
The maximum response time of this device is as follows:
● OFF response (ON status → OFF status): 10ms or less
● ON response (OFF status → ON status): 100ms or less
3-3 Auxiliary Output
This device is equipped with four auxiliary outputs as non-safety monitor outputs. In the case of
selecting preset logic, the setting is as follows:
AUX1
Negative logic of OUT1 / OUT2
AUX2
Negative logic of OUT3 / OUT4
AUX3
Reset trigger output
AUX4
Lockout output
Each auxiliary output operation can be changed to the following output operation by using the
software tool.
.”
●
Positive logic output or negative logic output of OUT1 / OUT2
●
Positive logic output or negative logic output of OUT3 / OUT4
●
Output A / B / C / D of diagnosis results of input block 1 / 2 / 3 / 4
●
Output E / F / G of diagnosis results of internal logical circuit
●
Reset trigger output
●
Lockout output
●
Muting indicator output
●
Monitor output of IN1 to 8
●
Normally OFF