Chapter 5
Operations — Using the web control function
224 - ENGLISH
[Detail control] page
Click [Projector control]
→
[Detail control].
4
5
6
3
2
1
8
7
9
10
11
1 Control of the projector
The projector is controlled by clicking the buttons in the same
way as the buttons on the remote control. After control, the on-
screen display of the projector at the right of the control page is
updated.
2 [SUB MEMORY]
Switches the sub memory.
3 [SYSTEM DAYLIGHT VIEW]
Switches to system daylight view settings.
4 [FREEZE]
Temporarily pauses the image.
5 [WAVEFORM MONITOR]
Displays the waveform of the input signal.
6 [PROJECTION METHOD]
Switches the setting of the projection method.
7 [OSD POSITION]
Switches the OSD position setting.
8 [GEOMETRY]
Switches the geometric adjustment setting.
9 [LENS]
Displays the [LENS] page.(
x
page 226)
10 [TEST PATTERN]
Displays the test pattern.
Click the test pattern to display in the projected image from the
pattern buttons displayed on the right side of the control page.
The display of the test pattern disappears if [Exit] is clicked.
11 [GET OSD]
Updates the on-screen display of the projector at the right of the
control page.
Registering the user test pattern
1) Click [Projector control]
→
[Detail control]
→
[TEST PATTERN].
f
The test pattern selection buttons are displayed at the right side of the control page and [USER TEST
PATTERN LIST] is displayed on the bottom right.
2) Click the [ADD] button of the user test pattern number to be registered.
f
Up to three user test patterns can be registered.
f
Number that user test pattern is not registered is displayed as [No such file.], and the [ADD] button is
displayed.
f
Number that user test pattern is already registered is displayed as the user test pattern name, and the
[EDIT] button is displayed.
f
Click the [ADD] button of the register destination to display the file selection screen.
3) Select the file of a test pattern to register, and click [Open].
f
The user test pattern name is displayed, and the registration is completed.
Note
f
To register a new test pattern to the number with the user test pattern already registered, delete the registered test pattern first, and then
perform the registration again. Registration by overwriting is not possible. For the procedure to delete, refer to “Deleting the registered user
test pattern” (
x
page 225).