169
4.
Loosen the M4 screws (2 screws for 1 fan), and
remove the fan guard and the fan itself from the
controller.
5.
Remove dust and dirt adhered onto the fan by air-blowing.
ワㄐㄕㄊㄆ
• Do not rinse the fan. This may cause failure of the electronic parts inside.
6.
Install the fans in the direction so that the air flow arrow on the fan points to the laser marker and the fan cable is on
the bottom side.
Put the fan guard on the fan and insert the screws (M4, depth 30 mm) into upper left and bottom right holes.
Airflow direction
Laser marker
ワㄐㄕㄊㄆ
• Install the controller fans in the direction so that the air flow matches the intake direction.
Fan installed in the wrong way causes the flow to go in the wrong way, which may failure of the product.
• Be careful not to let the cable get caught while installing.
7.
Fasten the screws (2 screws for 1 fan) from the top of the fan guard to secure the fan to the controller.
Screw size: M4
Tightening torque: 1.0 N·m
Fan guard
Fan
Screws
ME-LPRF-SM-11
Содержание LP-RF Series
Страница 17: ...1 Product Overview ME LPRF SM 11...
Страница 34: ...2 Laser Marker Installation ME LPRF SM 11...
Страница 57: ...3 Operation Method ME LPRF SM 11...
Страница 81: ...4 External Control Using I O ME LPRF SM 11...
Страница 126: ...5 External Control by Communication Commands ME LPRF SM 11...
Страница 135: ...6 Link Control with External Devices ME LPRF SM 11...
Страница 160: ...7 Maintenance ME LPRF SM 11...
Страница 186: ...Troubleshooting ME LPRF SM 11...
Страница 214: ...Index ME LPRF SM 11...
Страница 216: ...216 USB 32 55 W Warning 205 ME LPRF SM 11...
Страница 217: ......