2-3-5 Detaching / attaching the fiber unit
The fiber unit of this product can be removed from the head at the installation temporarily.
At the delivery state, the fiber unit is connected to the head.
Fiber unit
ワㄐㄕㄊㄆ
• The fiber cable cannot be removed from the controller side. Trying to disconnect the controller unit from the fiber cable
forcibly may cause a failure.
• It is recommended to connect the head and controller that have the identical serial numbers.
• The ingress protection characteristics of the head are ensured only when the fiber unit is mounted properly. Read this
chapter thoroughly for correct removal and installation.
• When the fiber unit is removed and re-installed, the lasing position might be misaligned relative to the guide laser
radiation position. To align the lasing position, calibrate the marking field with following the procedures described in the
“Laser Marker NAVI smart Operation Manual”.
Working conditions
WARNING
• Before the detaching or attaching the fiber unit, turn off the power supply and
disconnect the AC power cable. There is a risk of exposure to the laser beam
or electrical shock.
• Avoid oil mist, dust and dirt when removing or installing the fiber unit.
Items to be prepared
• Hexagon wrench (ball point, M5, L=150 mm)
• Scanner unit protection cover (Attached accessory)
• M5 screws (Attached accessories)
• Clean plastic bag as a protection cover of the fiber unit
• O-ring for fiber unit (Optional item)
• Air duster for optics
ME-LPRF-SM-11
Содержание LP-RF Series
Страница 17: ...1 Product Overview ME LPRF SM 11...
Страница 34: ...2 Laser Marker Installation ME LPRF SM 11...
Страница 57: ...3 Operation Method ME LPRF SM 11...
Страница 81: ...4 External Control Using I O ME LPRF SM 11...
Страница 126: ...5 External Control by Communication Commands ME LPRF SM 11...
Страница 135: ...6 Link Control with External Devices ME LPRF SM 11...
Страница 160: ...7 Maintenance ME LPRF SM 11...
Страница 186: ...Troubleshooting ME LPRF SM 11...
Страница 214: ...Index ME LPRF SM 11...
Страница 216: ...216 USB 32 55 W Warning 205 ME LPRF SM 11...
Страница 217: ......