3-1-2 Operation procedure with external control
Operation example when controlling the laser marker from external control devices such as
PLC
Turn ON key switch of laser marker controller
The device is ready for receiving the marking starting signal (trigger).
For LP-Mxxx-S type, open the laser gate to turn ON the ready signal.
Refer to “3-2-3 Shift to remote mode” (P.76).
Marking (Laser radiation)
Control by serial communication commands
I/O control
Open shutter
Select file
READY output ON
Marking trigger input ON
Laser pumping ON
Remote mode ON
about 20 seconds
Control by using I/O
or communication
commands
ンㄆㄇㄆㄓㄆㄏㄆ
• It is available to combine I/O and the serial communication for external control.
• Configure the environment setting in advance before using external control. Refer to “3-2 Before External Control”