140
9.
Adjust the “Power Correction Rate” so that the
measurement results by the power meter fall within
the optimum value.
Input range: 50 to 200 [%]
10.
Press [EXECUTE] after changing the power correction
rate.
ワㄐㄕㄊㄆ
• In case when the measurement results cannot be in the optimum range even after changing the power correction rate,
the laser marker may have a problem with the laser output performance. Contact our sales office.
ンㄆㄇㄆㄓㄆㄏㄆ
• The laser power correction refers to the function to correct not the maximum laser power [W] value, but the laser power
setting value.
• If the value of “Power correction” × “Laser power” is equal to or larger than 100, the setting will be “100”.
11.
Laser output optimization will start and it should take about
10 seconds.
ンㄆㄇㄆㄓㄆㄏㄆ
• In case of LP-M5xx-S/LP-M2xx-S type, the laser output optimization cannot be executed when the laser gate is closed.
After laser output optimization is started, input the signal from the external device and open the laser gate. Refer to “3-8
Control of Laser Gate” (P.117) for details.
12.
When the optimization is complete, the screen shown
right is will appears.
Press [CLOSE] to close the window.
ME-LPM-SSM-10
Содержание LP-M Series
Страница 16: ...16 MEMO ME LPM SSM 10...
Страница 27: ...27 Chapter 1 Specification ME LPM SSM 10...
Страница 37: ...37 Chapter 2 Preparation ME LPM SSM 10...
Страница 69: ...Chapter 3 Connection for External Control ME LPM SSM 10...
Страница 128: ...Chapter 4 Maintenance ME LPM SSM 10...
Страница 148: ...Troubleshooting ME LPM SSM 10...
Страница 169: ...Index ME LPM SSM 10...
Страница 172: ...172 MEMO No 9000 0066 34V ME LPM SSM 10...
Страница 173: ...No 9000 0066 34V...