50
Installation of air nozzle and removing dust by compressed air
[Only for LP-MA00 type]
Install the attached air nozzle (one piece) near the laser emission port and blow away dust or contaminant with the
compressed air to keep the laser emission port clean.
WARNING
• Never use the gas other than air. The laser beam may ignite the gas,
resulting in fire.
Air nozzle
Compressed air
Supply air type
Air from the
atmosphere
Recommended
pressure
0.2 to 0.5 MPa
ワㄐㄕㄊㄆ
• Remove oil or oil mist in a compressed air by using the filter or other equipment, and blow dried and clean compressed
air.
• Together with removing the dust by the compressed air, clean the protection glass of the laser emission port regularly.
Operating with the contaminated laser emission port may lead to deterioration in quality of laser marking or processing
and product failure. Refer to “4-2-1 Protection glass of laser emission port” (P.130).
• To prevent the damage to the piping of the compressed air by the laser beam and its reflected beam, cover the plastic
piping with the protective casing such as the metal casing with black coating.
Dimensions of attached air nozzle
Unit: mm
w
40
20
47
13
6.5
11
53.5
80
94
80
q
On the laser marker side
Material: Aluminum with anodic oxide coating
Weight: Approx. 135 g
No.
Description
q
Fixing hole (4 holes):
φ
6.5 through hole with a counterbore of
φ
11 and depth 10
w
Fixing hole of compressed air connection: M5 through hole
ME-LPM-SSM-10
Содержание LP-M Series
Страница 16: ...16 MEMO ME LPM SSM 10...
Страница 27: ...27 Chapter 1 Specification ME LPM SSM 10...
Страница 37: ...37 Chapter 2 Preparation ME LPM SSM 10...
Страница 69: ...Chapter 3 Connection for External Control ME LPM SSM 10...
Страница 128: ...Chapter 4 Maintenance ME LPM SSM 10...
Страница 148: ...Troubleshooting ME LPM SSM 10...
Страница 169: ...Index ME LPM SSM 10...
Страница 172: ...172 MEMO No 9000 0066 34V ME LPM SSM 10...
Страница 173: ...No 9000 0066 34V...