157
External control
Troubles
Causes
Measures
Communication with the
external device cannot
start.
Laser marker is not in remote mode.
Press Remote switch on front of controller or enter
remote mode in a manner described in “Safety /
Setup / Maintenance Guide”.
The wiring between the laser marker
and the external control devices is
incorrect.
Check connections with external equipment for
mis-connection, disconnection or contact failure
due to any loose connector.
Check for continuity using tester or the like.
There are noises coming from
surrounding equipment.
Protect laser marker against noises as follows:
• Securely ground frame ground terminal of laser
marker or surrounding equipment.
• Isolate power and signal lines from each other
if they have been routed in parallel.
• Shield signal line.
• Isolate power supply for laser marker from
other equipment.
• Use noise cut transformer to absorb noises
from power supply.
Serial communication
control fails
Selected communication port is
inappropriate.
For communication with external devices, select
either RS-232C or Ethernet port.
(They cannot be used at the same time, or
switched.)
The port selected in the environment setting
screen indicates the valid communication port.
RS-232C is selected at factory shipment.
The RS-232C cable is connected to the
wrong connector (RETURN OUT).
Connect the RS-232C cable to “RS-232C”
connector on the rear of the controller.
The connection of the communication
cable is incorrect.
• For RS-232C, use a commercially available
cross cable. (A straight cable cannot be used.)
Laser marker has three-wire connection. (Only
pins Nos. 2, 3 and 5 of RS-232C connector are
used.)
• For RS-232C connection, confirm the wiring
of the external device including the loop back
connection.
For Ethernet, check the followings:
• To use an external device and the laser marker
one to one, connect them with a commercially
available cross cable (STP cross cable of the
Category 5e or higher is recommended).
• To use an external device and the laser
markers one to many, prepare a hub or
router compliant to 1000BASE-T, 100BASE-
TX, or 10BASE-T and connect them with a
commercially available straight cable (STP
straight cable of the Category 5e or higher is
recommended).
Communication parameter settings are
incorrect.
• Match communication parameter settings to
external equipment. Communication parameter
settings of laser marker can be checked in the
environment setting screen.
• When using RS-232C, specify the “Flow
control” to “None” at the communication port
settings of the external control device.
ME-LPM-SSM-10
Содержание LP-M Series
Страница 16: ...16 MEMO ME LPM SSM 10...
Страница 27: ...27 Chapter 1 Specification ME LPM SSM 10...
Страница 37: ...37 Chapter 2 Preparation ME LPM SSM 10...
Страница 69: ...Chapter 3 Connection for External Control ME LPM SSM 10...
Страница 128: ...Chapter 4 Maintenance ME LPM SSM 10...
Страница 148: ...Troubleshooting ME LPM SSM 10...
Страница 169: ...Index ME LPM SSM 10...
Страница 172: ...172 MEMO No 9000 0066 34V ME LPM SSM 10...
Страница 173: ...No 9000 0066 34V...