3-5-5 Select file
T1
T2
T4
T5
T6
T4
T3
T2
T1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
READY OUT
MARKING OUT
SET OK OUT
TRIG. IN
SET IN
D0 to D15 IN
SELECT 0 to 2
IN
Item
Period
Remarks
T1
0.5 ms or more
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN
to D15 IN, turn on SET IN.
T2
0 ms or more
Keep the input until the SET OK turns ON.
T3
2 to 510 ms
One-shot output. Set the output time on the environment setting screen. There is a
margin for the setting value.
T4
―
• When laser pumping is completed:
Time for data creation. It varies depending on the quantity of data to be marked.
• When laser pumping is not completed:
Time for data creation or time for laser pumping, whichever is longer.
T5
0 ms or more
To input the next file number right after TRIGGER IN, input SET IN after MARKING OUT
turns ON.
T6
10 ms or more
Keep the ON status for 10 ms or more.
Input SELECT 0 to 2 as the table below.
Number input target
SELECT 0 (No. 20)
SELECT 1 (No. 21)
SELECT 2 (No. 22)
File No.
OFF
OFF
OFF
ンㄆㄇㄆㄓㄆㄏㄆ
• If marking is still being performed at the time SET input is turned to ON, the file will be changed after marking is
completed.
• TRIG. IN is acceptable while the READY is turned to ON.
ME-LPM-SSM-10
Содержание LP-M Series
Страница 16: ...16 MEMO ME LPM SSM 10...
Страница 27: ...27 Chapter 1 Specification ME LPM SSM 10...
Страница 37: ...37 Chapter 2 Preparation ME LPM SSM 10...
Страница 69: ...Chapter 3 Connection for External Control ME LPM SSM 10...
Страница 128: ...Chapter 4 Maintenance ME LPM SSM 10...
Страница 148: ...Troubleshooting ME LPM SSM 10...
Страница 169: ...Index ME LPM SSM 10...
Страница 172: ...172 MEMO No 9000 0066 34V ME LPM SSM 10...
Страница 173: ...No 9000 0066 34V...