81
Functions
Outline
Guide laser function*1
The marking position can be checked with the red guide laser. (Marking area, character
string to be marked and work image)
Dual pointer function*1
The work distance can visually be confirmed using the guide laser and laser pointer.
Marking time measurement Measures the period of marking. Marking laser is not irradiated during this operation.
Laser Setting
Laser power, scan speed and laser pulse cycle can be specified for each setting file.
Corrections can be made on a marking condition basis such as characters, logos, bar
codes, etc.
I/O check monitor
The I/O state of Input/Output terminal and I/O connector can be monitored.
Output simulation
Turn ON/OFF the output signals of laser marker on simulation. Check for proper
connection to external device.
Compatible communication
command
Communication command formats can be selected for the LP-F series (older model).
Error history display
For up to 64 errors, details of each error, and date and time of occurrence can be
displayed.
Operator adjustment
Adjustment items available to operators can be specified.
Laser power measurement
*1, *5
Measure the current value of laser power [W] and adjust the power setting value.
Marking Energy
Measurement *1, *2, *4
Each marking energy [J] is measured and error occurs if the energy is beyond the preset
threshold energy.
Power check *1, *6
Measure the current percentage of laser power in comparison with the default value.
Wire Breakage Detection
function *2
Detects the broken fiber wire and shuts off the laser power.
Unintended-irradiation
detection *2
Detects unexpected laser radiation and shuts off the laser power.
Uniform spot function *3
In order to ensure uniformity of the laser spot size in the marking area, marking is
performed with the spot size according to the specified surface.
Mark the space from N surface position to the specified surface height by the same spot
size.
The size and marking position (X/Y coordinates) for character, logo and bar code are
corrected according to the specified work distance.
Focus adjustment *9, *10
The focal length can be adjusted in the following range manually with the adjustment
control in the head.
LP-S200/S500: Approx. ±7 mm
LP-S202/S502: Approx. ±3 mm
LP-S205/S505: Approx. ±24 mm
Displacement input
function *11
On connecting the displacement sensor to the laser marker, the work distance is
controlled at input of the displacement sensor trigger according to the measured value.
*1 :
The function should be used as the guide. They are not the completely corrected values.
*2 :
Detection cannot be performed in some marking conditions.
*3 :
Only for LP-M/LP-Z series.
*4 :
Only for LP-M/LP-S series.
*5 :
Only for LP-M5xx/LP-M2xx/LP-Sxxx type.
*6 :
Only for LP-SxxxW type/LP-Z series.
*7 :
Only for LP-SxxxW type.
*8 :
The marking size and position are calibrated based on the calculation. Depending on the required marking quality,
adjustment of the marking conditions may be needed.
*9 :
Only for LP-Sxxx type.
*10 :
There are following precautions to use the focus adjustment function:
•
Optimal marking conditions may vary depending on marking object materials and desired marking quality.
•
Marking position may be deviated relative to the guide laser radiation position.
•
Measurements of marking energy measurement and laser output measurement/correction may vary.
*11 :
Only for LP-M series.
ME-LPMSZ-OP-7
Содержание LP-M Series
Страница 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Страница 76: ...76 MEMO ME LPMSZ OP 7 ...
Страница 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Страница 102: ...102 Symbol ME LPMSZ OP 7 ...
Страница 255: ...Troubleshooting ME LPMSZ OP 7 ...
Страница 276: ...Appendix ME LPMSZ OP 7 ...
Страница 304: ...Index ME LPMSZ OP 7 ...
Страница 307: ...No 9000 0063 56V ...
Страница 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...