Screen Description of Layer Condition
1
2
3
4
6
7
5
Description
1
Layer No.:
Specifies the layer No. to be edited. One marking face can be set per layer No.
Setting Range
0 to 15
2
Work Shape:
Specifies the work type of the 3D figure to be marked.
3
Center X / Center Y / Center Z :
Sets the coordinate of the center position of the 3D figure. (World coordinate)
Setting Range
-60.000 to +60.000 mm (LP-M500 / LP-Z130)*
Reference
• For the coordinate definition of 3D figures, refer to “Coordinate System (World Coordinate / Local Coordinate)” (P.135).
4
Rotation Angle X / Rotation Angle Y / Rotation Angle Z :
Sets the tilt angle of the 3D figure. Each axis becomes the center of the rotation, and with the + (plus) value, it
rotates in the counter-clockwise direction.
Setting Range of Rotation Angle X/Y -90.00 to +90.00 degree
Setting Range of Rotation Angle Z
-180.00 to +180.00 degree
5
Defocus :
Sets this condition when performing defocus marking.
Setting Range
-22.000 to +22.000 mm (LP-M series)
-25.000 to +25.000 mm (LP-Z series)
Reference
•
The defocus is adjustable by ±22 mm (for LP-M series) or ±25 mm (for LP-Z series)
from the specified work distance. In case of setting either Z offset or uniform spot
mode, set the summed distance with those offset and defocus to be within ±22 mm (for
LP-M series) or ±25 mm (for LP-Z series). If this summed distance exceeds the range
and the user starts marking, the error might occur.
•
When the uniform spot mode is set, only the minus value of the defocus is available.
Setting the defocus between 0 mm to +22 mm (for LP-M series) or +25 mm (for LP-Z
series) under the uniform spot mode set is invalid.
LP-M: +22 mm
LP-Z: +25 mm
LP-M: -22 mm
LP-Z: -25 mm
ME-LPMSZ-OP-7
Содержание LP-M Series
Страница 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Страница 76: ...76 MEMO ME LPMSZ OP 7 ...
Страница 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Страница 102: ...102 Symbol ME LPMSZ OP 7 ...
Страница 255: ...Troubleshooting ME LPMSZ OP 7 ...
Страница 276: ...Appendix ME LPMSZ OP 7 ...
Страница 304: ...Index ME LPMSZ OP 7 ...
Страница 307: ...No 9000 0063 56V ...
Страница 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...