242
Measurement result window
1
5
6
7
8
2
3
4
Item
Description
1
Measurement
Power
: Measurement result in Watt.
2
Initial Ratio (of
Laser Power)
: The current power percentage relative to initial power.
Reference
• The “Current-to-initial power ratio” field shows the relative value expressed as a percentage of the initial power of the
laser oscillator.
•
The value of the “Current-to-initial power ratio” is indicated only when the measurement has been made with the “Laser
power setting” being “100”.
Otherwise, the “Current-to-initial power ratio” field shows “---”.
3
Setting Power
: Set the output level [%] of laser power.
4
Laser Rad. Time
(Laser Radiation
Time)
: Displays the total time of the laser radiation.
5
MEASURE
: Press to measure the laser power.
For details, refer to “Laser power measurement” (P.241).
6
CORRECT
: Press to correct the laser power.
Refer to “2-9-3 Lot” (P.122) for details.
7
OPTIMIZE
: Press to optimize the laser output power according to the installation condition of the
laser marker. Refer to “Laser Output Optimize” (P.237) for details.
8
CLOSE
: Returns to the environment setting screen.
To use this function
• The laser output from the fiber laser oscillator in this system declines over time.
•
After the installation, replacement or moving laser marker, the marking energy measurement results may change.
• In case of LP-Sxxx type, after the fiber unit is removed/attached, or focus is adjusted (Refer to “Safety / Setup /
Maintenance Guide”.), the marking energy measurement results may change.
•
Use “Laser Output Optimize” (P.237) function to improves the accuracy of “Laser output measurement/correction” results
after the installation, replacement or moving of laser marker.
•
Measurement / correction function is available when laser pumping is completed, and the internal shutter is closed.
•
For LP-M5xx-S / M2xx-S type, laser power measurement is available when the laser gate is opened.
•
The measurement results might have +/-5% difference with normal temperature (20 to 30 Celsius degree).
•
The +/-10% difference might occur under the high/low temperature. Correcting power under normal temperature is
recommended.
ME-LPMSZ-OP-7
Содержание LP-M Series
Страница 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Страница 76: ...76 MEMO ME LPMSZ OP 7 ...
Страница 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Страница 102: ...102 Symbol ME LPMSZ OP 7 ...
Страница 255: ...Troubleshooting ME LPMSZ OP 7 ...
Страница 276: ...Appendix ME LPMSZ OP 7 ...
Страница 304: ...Index ME LPMSZ OP 7 ...
Страница 307: ...No 9000 0063 56V ...
Страница 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...