27 Troubleshooting
Cause:
There is an alarm or a warning.
Remedy:
• If there is an alarm, only these commands can be transmitted:
Status check (
STS
)
I/O monitor (
IOM
)
Operating data (
RTD
)
Error history (
ERH
)
Alarm reset (
ARS
)
Error number (
ENO
)
• If there is a warning, only these commands can be transmitted:
Status check (
STS
)
I/O monitor (
IOM
)
Operating data (
RTD
)
Error history (
ERH
)
Alarm reset (
ARS
)
Error number (
ENO
)
Shutter control (
SHT
); close request and status request only
Reception mode (
MKM
); read request only
For LP-400/V compatibility mode, different commands apply. For
details, refer to the “Serial Communication Command Guide: LP-400/
V compatible mode”.
Cause:
Two or more commands are transmitted at the same time.
Remedy:
When you send a command, always confirm the response from the laser
marking system before sending the next command.
Cause:
The “LP-400/V compatibility” setting is wrong.
Remedy:
• To use the command format of the LP-400/V series, select the
command mode “LP-400/V compatibility” in the “System settings” of
Laser Marker NAVI smart.
• To use the standard command format, disable “LP-400/V
compatibility” or switch the command mode with the Command mode
(
RSM
) command.
ME-NAVIS2-OP-1
315